If a slave with the extended addressing mode is used in combination
with a master of the first generation (version 2.0), an address between
1A and 31A must be assigned to this slave.
AC5295
4 inputs
AS-i profile S-0.A.E / extended addressing mode: yes
Data bit
Input
Socket
L-
3
I-1/2
2
I2
L-
3
I-3/4
2
I4
Electrical connection
Connect the connectors of the sensors/actuators to the M12 sockets.
To ensure the protection rating IP 67 you must
• cover the unused sockets with protective caps (E73004)*, tightening
torque 0.6...0.8 Nm.
• use the flat cable end seal (E70413)* if the module is at the end of
the cable line.
*) to be ordered separately
6
D0
D1
I1
I-1/2
I-1/2
I1
inputs
4
1
L+
L-
I2
3
4
I-2
I3
2
1
4
L+
1
L+
L-
I4
3
4
I-4
2
1
L+
D2
I2
I 3
I-2
I-3/4
D3
I4
I-3/4
I-4

Werbung