Please note: Next to the drainage opening there is an "emergency opening" which
is used to drain the water into the water tank if the drainage opening is blocked or if
a vacuum has been formed. If the water leaks out of the emergency opening, please
go through the following steps:
o Please check if the drainage opening is not blocked.
o Please check whether the drainage hose has not been kinked
o Please squeeze the drainage hose a few times to remove the vacuum
o Please shorten the drainage hose a bit
Maintenance
To avoid injuries, please switch off the device and disconnect the power plug before starting maintenance or cleaning.
Cleaning
Please disconnect the power plug.
Please clean the device with a dry and soft cloth. For heavy dirt, please use a lightly wet cloth.
Please do not use chemical solvents (such as gasoline, alcohol, etc.). The surface as well as the whole housing
could be damaged.
Cleaning the filter
Please open the filter cover and carefully remove the filter.
To remove the dust from the filter, please use a vacuum cleaner or dab it
lightly.
If the filter is very dirty, wash it in water with neutral detergent, rinse well
with water and let it dry.
The active carbon filter can be replaced if necessary. You can get
replacement filters from your vendor:
o Item no.: 16882
o Item name: DryFix 20 Lumio/ PRO active carbon filter
o Brand: Suntec Wellness
Carefully insert the filter back into the unit and close the filter cover.
Storage
• Please unplug the unit and bundle the power cord.
• Please empty the water tank, wipe out the tank with a cloth and reinstall it.
• Please clean the air filter as described above and then reinstall it in the unit.
• For storage, place the unit in an upright position and avoid direct sunlight.
Troubleshooting
problem
The unit is not working
The dehumidification
performance is insufficient
cause
Is the unit connected to the power
source?
Is the 'water tank full' indicator
lighting up (water tank is full or
incorrectly placed)?
Is the water tank installed correctly?
Are the air outlet slats open?
The unit is in defrost mode.
Is the air inlet or outlet blocked?
Is the air filter dirty?
Does the unit operate in the fan
mode?
Is the room temperature/humidity too
low high?
Drainage hole
solution
Plug-in the unit.
Empty the water tank and install it correctly.
Please check the position of the water tank.
Please open the air outlet slats.
This is a normal process and helps to protect
internal parts. Once the process is complete,
the unit returns to normal operation.
Check the air inlet and outlet and remove
any obstructing objects
Clean the air filter as described in the
operating instructions
Please switch to dehumidification mode.
The unit should be operated at the air
temperature of 5°C - 32°C and a humidity of
10%-90%. The unit cannot dehumidify the air
optimally at ambient temperature and/or
humidity level below/above this.
Emergency opening