7. When cleaning is completed, start up the cabinet.
See section Starting up.
Check at regular intervals also that
• the operating noise of the cabinet is normal,
• the evaporator is clean and
• the inlet and outlet grids are not obstructed or dirty.
NOTE
Clean the drain sump located in the machinery compartment. Inadequate or
infrequent cleaning may shorten the service life of the electric heater / hot gas
piping for the drain sump. Detergent residues must be cleaned without delay
from the tray.
NOTE
In the event of a refrigerant leakage all products displayed in the cabinet must
be disposed of and then the cabinet must be cleaned.
5.1. Cleaning condenser
Check once a month, or more often if necessary, that the condenser is clean. The condenser is
located at the back of the cabinet on the service side behind a detachable grid.
Carry out the following procedures when necessary.
1. Vacuum the condenser fins and check that the spaces between the
fins are unobstructed.
2. Pull the top edge of the plate outwards and turn the plate downwards.
NOTE
When the cabinet is disconnected from the mains supply,
the sump heater or pump will not operate and drain water or
cleaning liquid may fill the evaporation sump.
NOTE
Access the TectoPromo FL2 Aida condensing unit by removing the detachable
wire grid. See figure 3, item E on the inside cover.
6. Interruptions in electricity distribution
The cabinet will start up automatically after a power cut or an interruption in the electricity
supply. The evaporation drain sump may overflow during a power cut. After a power cut, check
that the cabinet operates normally. If necessary, contact your nearest service organisation.