Herunterladen Diese Seite drucken

Suntec Wellness KLIMATRONIC ADVANCE 9.0 Eco R290 Bedienungsanleitung Seite 17

Mobiles lokales klimagerät

Werbung

2.1 Cooling Mode
- Please select the cooling mode to lower the temperature in your room
- Please press the MODE button repeatedly until the "Cool" indicator lights up.
- Press the up/down button to set the temperature. The temperature can be set between 16℃ and
30℃.
- Please press the fan speed button repeatedly until the desired indicator lights up.
Please press the oscillation button on the remote control in order to activate or deactivate the
automatic vertical movements of the fins.
NOTE: The air conditioner stops when the room temperature is below the set temperature.
2.2 Fan Mode
- Please press the MODE key repeatedly until the "Fan" indicator lights up.
In ventilation mode, the room air is circulated but not cooled.
- Please press the SPEED button to select high, medium or low speed.
2.3 Dehumidification Mode
- Press the MODE button on the control panel or remote control until the "Dry" indicator lights up. The
fan speed cannot be selected. The user should connect the drainage hose to the drain at the bottom
of the unit.
Note: In this mode, the fan speed switches to Low and cannot be set.
2.4 Oscillation
Please press the oscillation button on the remote control in order to activate or deactivate the
automatic vertical movements of the fins.
3. TIMER 1h-24h:
When the unit is switched on, press the TIMER button first. Now you can set the desired switch-off time
with the up/down buttons.
When the unit is switched off, press the TIMER key to set the switch-on time.
4. Automatic Frost Protection:
At low room temperatures, frost may accumulate on the evaporator during operation. In this case,
the unit automatically starts defrosting and the POWER LED flashes. The defrost control sequence
is as follows:
- When the unit is operating in cooling mode or dehumidification mode, the ambient temperature
sensor detects the evaporator coil temperature. As soon as this drops below -1°C, the compressor
is switched off. After the compressor has stopped operating for 10 minutes or reaches the coil
temperature 7℃, the unit restarts in cooling mode.
5. Overload Protection:
In the event of a power failure, there is a 3-minute delay until the compressor restarts to protect the
compressor.
Emptying of the water tank
Please switch off the appliance before emptying the water tank.
Remove the plug from the water outlet and keep it in a safe area. Please connect the drain hose securely and
properly and ensure that it is not kinked and free of obstacles. Please place the hose outlet over a drain or
bucket and make sure that the water can escape freely from the unit. Please do not immerse the end of the
hose in water, as this may result in an "air lock" in the hose.

Werbung

loading

Diese Anleitung auch für:

Klimatronic advance 12.0 eco r290