INSTRUCTION ON MOUNTING AND USE
Check also the drawings on the initial pages with the alphabetical
and numerical references in the explanatory text.
Closely follow the instructions in this manual. We cannot
accept liability for any faults, detriment or fire damage to the
appliance due to non-compliance with the manual's
instructions. Installation and electrical connections must be
executed by a qualified technician. You should affix the hood
to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard. Do not install it inside a cupboard.
Use
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe not supplied).
If cooking fumes and vapours cannot be externally discharged,
the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
Electrical connection
Make sure that there is a power socket near the hood and
that the system has a 30 mA differential. The mains voltage
must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it
does have a plug, connect the hood to an accessible
approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum
contact opening of no less than 3 mm (accessible). This
installation and electrical connection must be executed by a
qualified technician.
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
For the correct use please carefully read the intructions below.
Hood in stand-by: LED LIGHT SWITCHED OFF
1st suction speed (power) -GREEN LED LIGHT
2nd suction speed (power) . ORANGE LED LIGHT (amber)
3rd suction speed (power) - RED LED LIGHT
4th suction speed (power) - RED LED LIGHT (FLASHING)
Note: The 4th suction speed (power) stays on for 5 minutes,
after which the suction motor will position itself on the 2nd
speed.
Grease filters need cleaning: FLASHING GREEN LED light
(read instructions found under .Reset and configuration for
filter saturation signal.)
Coal filters must be cleaned or replaced: FLASHING
ORANGE (amber) LED light (read instructions found under
.Reset and configuration for filter saturation signal.)
Using the remote control
The remote control is able to control all the functions of the
hood:
Select the suction speed (power)
Control the central light
Reset e configure the saturation of the filters signal
Selecting the suction speed (power):
Press the „ " key or the „ " key until you see the symbol
relating to the .Select the suction speed (power). function.
Press the .+. key or the .-. key or the „ " key respectively to
increase or diminish or switch off (stand-by) the speed
(suction power).
Controlling the central light:
Press the „ " key or the „ " key until seeing the symbol
relating to the .Controlling the central light. function on the
remote control.
The central light can be switched on and off in two ways:
1. Press the .+. key or the .-. key respectively to switch the
central light (ON) or (OFF).
2. Press the „ " key to change the state of the light from
(OFF) to (ON) or vice versa.
Resetting and configuring the saturation of the filters
signal
Switch the hood on at any speed (see paragraph above
.Selecting the suction speed (power.).
Press the „ " key or the „ " key until seeing the symbol
relating to the .Resetting and configuration of the saturation of
the filters signal. function on the remote control.
Resetting the anti-fat filter saturation signal (GREEN LED
FLASHING on the control bar)
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Press the .+. and .-. keys contemporaneously for about 3
seconds. The LED stops flashing, indicating that the resetting
of the signal has been accomplished.
Resetting the carbon filter saturation signal (ORANGE
(amber) LED FLASHING)
Note! The reset of the carbon filter saturation signal is
normally deactivated. To activate it, see under paragraph
.Activating the carbon filter saturation signal..
First proceed with the maintenance of the filter as
described in the corresponding paragraph.
Press the .+. and .-. keys contemporaneously for about 3
seconds. The LED stops flashing, indicating that the resetting
of the signal has been accomplished.
Deactivating the carbon filter saturation signal (for
special applications)
Switch the hood off (see paragraph above .Selecting the
suction speed (power).).
Press the „ " key or the „ " key until seeing the symbol
relating to the .Resetting and configuration of the filters
saturation signal. function on the remote control.
Press keys .+. and .-. contemporaneously for about 3
seconds. The LED flashes in GREEN to indicate that the
carbon filter saturation signal has been deactivated.
To reactivate the carbon filter saturation signal, repeat the
operation. The LED flashes in ORANGE.
Maintenance of the remote control
Cleaning the remote control:
Clean the remote control with a damp cloth and a neutral
solution of detergent without abrasive substances.
Changing the battery:
. Open the battery casing using a small screwdriver with a
flat point.
. Change the finished battery with a new one of 12 V type
MN21/23
In inserting the new battery respect the polarity indicated
on the battery casing!
. Close the battery casing up again.