User's manual for AMC
All other components are not essential for
operation of the motor control unit.
The control unit can thus be installed and
made ready for operation quickly and eas-
ily. Switches and instruments suitable for
your vehicle can then be arranged and
wired up subsequently.
A 5-10kOhm potentiometer is suitable for
use as the accelerator pedal. We recom-
mend the LM5k listed in our catalogue.
Please refer to the diagrams "Operation /
Pedal operation" for further information
on the potentiometer.
All terminals for the operating controls are
galvanically isolated from the battery. The
appropriate cable is supplied complete
with a plug connector. We recommend the
use of the IF25D interface, which simpli-
fies and rationalises connection of the op-
erating controls cable.
The emergency-off switch and cooling fan
outputs are at battery potential.
10.02.03 - AMCxxx_16.doc
Alle anderen Elemente sind für die Funktion
der Drehstromsteuerung nicht erforderlich.
Damit ist es möglich, die Steuerung mit gerin-
gem Aufwand in Betrieb zu nehmen, an-
schliessend können Sie die für Ihr Fahrzeug-
design geeigneten Schalter organisieren und
definitiv verdrahten.
Als Fahrpedal ist jedes Potentiometer von 5 -
10kOhm geeignet. Wir empfehlen das LM5k
in unserem Katalog.
Weiteres zum Potentiometer siehe Abbildung
"Bedienung".
Alle Anschlüsse der Bedienung sind von der
Batterie galvanisch getrennt. Das zugehörigen
Kabel wird mit dem Stecker mitgeliefert. Wir
empfehlen die Verwendung des Interfacebau-
steins IF25D zur einfachen und rationellen
Verdrahtung des Bedienungskabels.
Not-Aus und Ventilatorausgang sind auf Bat-
teriepotential.