5.2

Electrical connection

Wire in the apparatus according to the electrical supply required by the actuator (see label on product),
following the table below.
230Vac supply
0
Yellow/Green Earth
1
Blue or Gray Neutral / Common
2
Black
Phase / Open
3
Brown
Phase /Closed
4
White
Data (2/3/4 W-Net actuators)
5
Yellow
Data (2/3/4 W-Net actuators)
6
Green
Data (2/3/4 W-Net actuators)
Electric 230Vac wiring
0
1
2
3
Electric 230Vac wiring
(2/3/4 W-Net actuators)
4
5
6
0
1
2
3
N
110/230V~ 50/60Hz F
4
4
5
5
6
6
N
110/230V~ 50/60Hz F
24Vdc supply
1
Blue
Positive
2
Brown
Negative
4
White
Data (2/3/4 W-Net actuators)
5
Yellow
Data (2/3/4 W-Net actuators)
6
Green
Data (2/3/4 W-Net actuators)
Electric 24V dc wiring
1
2
Electric 24V dc wiring
(2/3/4 W-Net actuators)
4
4
5
5
6
6
1
2
+
24 Vdc
-
4
5
6
+
24 Vdc
-