Herunterladen Diese Seite drucken

HANSGROHE Metris 31652000 Gebrauchsanleitung, Montageanleitung Seite 4

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Crossflow
Assembly (see page 35)
English
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 37)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Dimensions (see page 38)
Flow diagram (see page 38)
free flow
Spare parts (see page 39)
XXX = Colors
000 = Chrome Plated
340 = Brushed Black Chrome
Cleaning (see page 41)
Operation (see page 40)
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
Test certificate (see page 42)
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange cartridge

Werbung