Verfügbare Sprachen

6
Gas Hook-Up Instruc琀椀ons
WARNING!
EN
!
materials when installed with zero clearance liner Part No. BI-3323-ZCL, and must be installed and
serviced by a quali昀椀ed installer to local codes.
WARNING!
when not installed with zero clearance liner Part No. BI-3323-ZCL.
WARNING!
the grill. If the supply pressure is greater, a regulator must be installed.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instruc琀椀ons. A 昀氀exible metal connector is included to
simplify the installa琀椀on of the unit. Connect this 昀氀exible metal connector to the 昀氀are 昀椀琀�ng on the end of
the manifold. Connect the other end of the connector to the gas piping. Ensure that the connector does
not pass through a wall, 昀氀oor, ceiling or par琀椀琀椀on, and is protected from damage. Do not use a hose to
connect the unit except to connect the cylinder regulator to the piping system. It must be connected with
rigid pipe, copper tube or an approved 昀氀exible metal connector which complies with na琀椀onal and regional
codes.
The installa琀椀on must comply with na琀椀onal and regional codes. The gas supply pipe must be su昀케ciently
sized to supply the kW input speci昀椀ed on the ra琀椀ng plate, based on the length of the piping run. If
installing a side burner, a separate line must be branched o昀昀 to the side burner unit and enter the side
burner opening at the speci昀椀ed loca琀椀on. If the enclosure is to house a propane cylinder, the tank por琀椀on
of the enclosure must be ven琀椀lated according to local codes, and must not have communica琀椀on with the
cavity used to enclose the gas grill. A propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed ven琀椀la琀椀on opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 130 cm
for a cylinder up to 9 kg and 195 cm
2. At least one ven琀椀la琀椀on opening on the exposed, exterior side of the enclosure located 25.4 mm or less
from the 昀氀oor level. The opening must have a total free area of more than 65 cm
and 100 cm
昀氀oor level.
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
25.4mm
MAXIMUM
www.napoleon.com
This grill is designed for installa琀椀on in a built-in enclosure constructed of combus琀椀ble
Cabinet frame, cabinet, and counter top must be made from non-combus琀椀ble material
The pressure supplied to the grill must conform to what is listed on the ra琀椀ng plate of
2
for a for a cylinder larger than 9 kg. The upper edge must be no more than 127 mm above the
OPENING
A
127mm
MAXIMUM
864mm
RECOMMENDED
OPENING
B
127mm
MAXIMUM
2
for a cylinder larger than 9 kg.
51mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
CYLINDER SIZE
OPENING A AREA
20 lb (9.1kg)
2
20in
(130cm
30 lb (13.6kg)
2
30in
(195cm
2
for a cylinder up to 9 kg
NON LOCKING DOOR
OPENING B AREA
2
2
2
)
10in
(65cm
)
2
2
2
)
15in
(100cm
)
N415-0541CE-GB-DE July 15.20
2