Herunterladen Diese Seite drucken

Novoferm N-423 Bedienungsanleitung Seite 66

Vorschau ausblenden Andere Handbücher für N-423:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4.9
Special settings
4.9.1 Opening the special settings menu
1. To open the menu for special settings, keep the programming button (PROG
button) (D) pressed in for approximately 3 seconds.
ð The display shows "3".
2. Press the programming button (PROG button) (D) again.
ð The display shows "4".
3. Keep the programming button (PROG button) (D) pressed in again for ap-
proximately 3 seconds.
ð The display shows "5".
4.9.2 Menu 5 + Menu 6: Force limits for opening and closing
Crush hazard at the door!
WARNING
If the force limits are set too high, there is a risk of personal injury.
The factory setting is "6" for opening and "4" for closing.
NOTICE
1. Select menu item "5".
ð After approximately 2 seconds, the display flashes and the set value for
the force limit for opening appears.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
3. Press the programming button (PROG button)  (D). The display shows  "6".
After approximately 2 seconds, the display flashes and the set value for the
force limit for closure appears.
4. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
5. Press the programming button (PROG button) (D).
ð The display shows "7".
64 - EN
The force on the main closure side must not exceed 400  N  /
750 ms!
We recommend performing door adjustments according to
menu 8 before carrying out the force learning cycle.

Werbung

loading