4.3
Scope of delivery
The scope of delivery is determined by the product configuration. It usually com-
prises the following:
1x
12
1x
16
4x
2
Fig. 5: Scope of delivery
1. Drive head including LED module
2. Pinion*
3. Rail (model example) drive side
4. Carriage*
5. Toothed belt or chain*
6. Deflection roller*
7. Rail connector (model example)*
8. Rail (model example) door side*
9. Tensioner*
10. Wall bracket*
*Optional
NOTICE
Check the supplied screws and wall plugs to make sure that they
are suitable for the structural condition on the installation site.
52 - EN
1
1x
2x
15
1x
3
11
13
1x
18
5
8
7
17
1x
11. Door connector attachment
12. Linking bar
13. Central support
14. Bag of screws
15. Handheld transmitter (depending on the
model)*
16. Ceiling mounting
17. Mains cable, 1.2 m length
18. Mounting bracket
19. Warning label
10
1x
6
4
1x
19
Automatic Door
WARNUNG: Automatisches Tor - Nicht im Bewegungsbereich des
Tores aufhalten, da sich das Tor unerwartet in Bewegung setzen kann!
WARNING: Automatic door - The door may operate unexpectedly,
therefore do not allow anything/anyone to stay in the path of the door!
14
1x
9