No. 882289 E Edition 1308
Technical data
Working range Sa min.
Working range Sa max.
Linear range Sl min.
Linear range Sl max.
Linearity error max.
Rated operating dist. Se
Repeat accuracy
Ambient temperature Ta min.
Ambient temperature Ta max.
Opt. working temperature min.
Opt. working temperature max.
Adjustment indicator
Power indicator
Electrical data
Eff. operating voltage Ue DC
Operating volt. UB min. DC (Ua)
Operating volt. UB max. DC (Ua)
Ripple max. (% of Ue)
Rated insulation voltage Ui
Rated frequency, AC
Output current at Sl min.
Output current at Sl max.
Output current at Se
Load resistance RL min.
No-load current max. Io at Ue
Short circuit protected
Protected against miswiring
Polarity reversal protected
Mechanical data
Housing material
Tightening torque
Sensing face material
Connection type
Cable jacket material
Cable diameter D max.
Cable short description
Cable Length
Number of conductors
Conductor cross section
Cable Screen
Enclosure Type per IEC 60529
Shock rating
Vibration rating
Degree of contamination
Approvals
Remarks
The position encoder can be moved in the range
D=0.5mm to 2mm in front of the active surface in the
measurement direction (see installation diagram). The
resulting non-linearity of the output signal is minimal in
the distance range D=1.0mm to 1.75mm.
4
0
mm
14
mm
0
mm
14
mm
±250
µm
7
mm
±80
µm
-25
°C
+70
°C
10
°C
50
°C
yes
no
24
V
15
V
30
V
10
75
VDC
DC
4
mA
20
mA
12
mA
500
Ohm
20
mA
yes
yes
yes
PA
0.5
Nm
PA
Cable
PUR
3.0
mm
Li9Y-11Y-0
2.0
m
3
0.14
mm²
no
IP67
Half-sinus 30gn,11ms
55Hz, 1mm ampl., 3x30min
3
CE
Position encoder
BAM TG-XE-001
BAM TG-XE-002

Werbung