5.1 IS THERE A PROBLEM WITH CERAMIC BURNER (4Z-HEG22)?
The cooking zones have become soiled.
This may be caused by burnt on remnants of food. This will not affect the working of the
appliance. However, you should make sure that the cleaning instructions are being followed
regularly.
The residual heat indicator cannot work.
If the cooking zone does appear to be hotter than 60℃ and the residual heat indicator has not
come on, you should call the Service Department.
After checked all of these, the gas hob still does not work properly, please call the Customer
Service Center and inform them of:
Tile type of problem.
--
The gas hob model number (Model....) as indicated on the packing carton.
--
Never call the technicians who is not authorized by your supplier, and refuse to use the spare
parts which are not from manufacturer.
6 INSTALLATION INSTRUCTIONS FOR BUILT-IN-HOBS
The following instructions are directed at the qualified installer so that the installation and
maintenance procedures may be followed in the most professional and expert manner possible.
Important: Unplug the electrical connection before performing any maintenance or
regulation upkeep work.
Positioning for gas hob
Important: this unit may be installed and used only in permanently ventilated rooms according to
the British Standards Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891 Current
Editions.
The following requirements must be observed:
a) The room must be fitted with a ventilation system which vents smoke and gases from
combustion to the outside. This must be done by means of a hood or electric ventilator that
turns on automatically each time the hood is operated.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
b) The room must also allow for the influx of the air needed for proper combustion. The flow of
air for combustion purposes must not be less than 2 m³/h per kW of installed capacity. The
supply of said air can be effected by means of direct influx from the outside through a duct
with a inner cross section of at least 100cm² which must not be able to be accidentally
blocked. Those appliances which are not fitted with a safety device to prevent the flame from
accidentally going out must have a ventilation opening twice the size otherwise required, i.e. a
minimum of 200 cm² (Fig. 3). Otherwise, the room can be vented indirectly through adjacent
rooms fitted with ventilation ducts to the outside as described above, as long as the adjacent
rooms are not shared areas, bedrooms or present the risk of fire (Fig. 4).
Directly to the Outside