Fan adjustments
The fan is adjusted and fully operable with the following default settings:
Air capacity
(m
3
/h, Adapter Ø125/Ø100mm):
24 HOURS mode 40/33
SILENT mode
83/72
MAX mode
97/82
Standby mode
0
To adjust the settings, please follow the instructions below.
SILENT mode speed adjustment
Control Panel:
Press
or
once, the number of
active indicator lights on the control
panel will show the current speed.
Press
to increase, or
crease the speed, according to the
following table:
Lights
Air capacity
Ø100 mm
(m
3
/h)
Ø125 mm
Humidity extraction: MAX mode
Turn-on delay time: 0 min
Off-delay time: 5 min
Humidity extraction time: 30 min
Motion sensor (I FAN Move) included
Remote control, area of QUIET button:
Press
or
indicator lights on the control panel
will show the current speed. Press
to de-
to increase, or
speed, according to the following
table:
1
2
3
4
5
33
37
41
45
49
40
44
48
52
57
, the number of active
to decrease the
6
7
8
9
10
53
57
61
66
72
62
67
72
77
83
GB