Herunterladen Diese Seite drucken

Bamo NivOil Bedienungsanleitung Seite 28

Öl-/leichtflüssigkeitsabscheider-überwachung
Vorschau ausblenden Andere Handbücher für NivOil:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TEST MODE
The device has an integrated test function. It can be activated as follows:
- Press the test button (at least 1 second)
- Self-check is started
- LEDs are blinking...
- Controlling the buzzer
- Checking the connection values of the corresponding probe
(correct type?, short circuit?, broken cable?)
Test passed
Test not passed
MAINTENANCE
When used as intended, the sensor supply unit / control unit (NivOil CU) and the probes are maintenance-free.
After an alarm has been detected, the probes must also be cleaned after cleaning the light liquid separator.
The probes can be cleaned of the adhesive grease/oil film with commercially available, grease-dissolving cleaners.
Note!
Electrostatic discharging must be prevented during cleaning. Clean with a damp cloth only!
SPECIAL CHARACTERISTICS
Oil probe (NivOil OP)
The oil/light liquid layer can no longer be detected correctly, if it is mixed with other chemicals such as surfactants, emulsifiers, etc.
Sludge probe (NivOil SP)
The probe may only be used in liquids to which PVC is sufficiently resistant.
EN
M-531.01-EN-AK du 30-06-2023 - Manufacturer : BAMO IER - Pirnaer Straße 24, D-68309 Mannheim - Germany (Translated document)
= the corresponding LED is lit in green
= the corresponding LED is blinking in green
·

Werbung

loading