TECHNICAL DATA (continuation)
Oil Probe (NivOil OP)
For connection to the sensor power supply unit (NivOil CU)!
Sensor material
Cable
Cable colour
Dimensions
Protection
Measuring principle
Ambient temperature
EU Type Examination Certificate BVS 07 ATEX E 091 X
Ex-maximum values
Maximum input voltage Ui
Maximum input current Ii
Maximum input power Pi
Maximum internal capacity Ci
Maximum internal inductance Li
Ex marking
Interconnection
Special conditions for safe use
The oil probe connection cable must be routed through the separation between areas with category 1G requirements and less hazardous
areas in such a way that protection class IP67 in accordance with EN 60529 is guaranteed.
The oil probe (NivOil OP) and the connecting cable may only be used in areas where electrostatic discharges cannot occur.
The technical information on the use of the oil probe (NivOil OP) in connection with aggressive/corrosive media must be observed.
EN
M-531.01-EN-AK du 30-06-2023 - Manufacturer : BAMO IER - Pirnaer Straße 24, D-68309 Mannheim - Germany (Translated document)
PE-EL with stainless steel sensor
Standard with 10m oil/petrol resistant cable 2x1mm²
Other cable lengths on request
Maximum permissible cable length: 300m
[C ≤ 200 nF/km and L ≤ 1mH/km]
blue
approx. Ø32x250mm incl. cable support sleeve with 5cm marks for height adjustment
IP68
capacitive, high frequency
-20°C...+60°C
17.9V DC
157mA
695mW
60nF
(no mixed parameters)
0.3mH
(no mixed parameters)
㐀 II 1G Ex ia IIB T4 Ga
(intrinsically safe electrical equipment)
Sensor supply unit (NivOil CU) with oil probe (NivOil OP)
·

Werbung