3. System setting codes

20 / 48 | EN
Monitored code
If two people enter their code one after the other, the lock
opens for a specific time interval (adjustable: 1 – 9
seconds).
What is important here is that a "monitored code" has been
entered twice in succession. The combination of monitored
codes is arbitrary.
Programming:
{Prog. code}-{*}-{33}-{*}-{117}-{*}-{requested code}-{*}-
{additional code or * to exit}
Master Code
Opens the lock for a pre-set time (adjustable: 1 – 9
seconds), even if the lock is locked by entering the locking
code or because the battery is too flat.
Programming:
{Prog. code}-{*}-{33}-{*}-{119}-{*}-{requested code}-{*}-
{additional code or * to exit}
3. System setting codes
Changing the programming code
All PIN code terminals supplied contain the programming
code 97531 when delivered. You must change this code im-
mediately for security reasons. All pre-set codes are deleted
when the programming code is changed for the first time.