2. Code types, their function and programming
Function of operator codes
2. Code types, their function and programming
Default settings
Programming code
Default Code
Toggle code
Blocking code
* Deleted when programming code is first changed.
Default code
Opens the lock for a pre-set time (adjustable: 1 – 9
seconds).
Programming:
{Prog. code}-{*}-{3}-{*}-{requested code}-{*}-{additional
code or * to exit}
Toggle code
Opens the lock for an unspecified time. Re-entering this
code re-locks the lock.
Programming:
Default, toggle, locking,
blocking, one-time, mon-
itored and master code
97531
13579*
135135*
9115*
18 / 48 | EN