temperature dependent and remains on maximum throughout the year. If a skimmer, a satellite filter or an InScenio
control unit (OASE accessories!) is used, it might be recommendable to deactivate the SFC, depending on the unit.
Pos: 43 /Pumpen/Schlammsauger/Aquamax ECO R/Montage Aquamax ECO R @ 8\mod_1221034064546_121.doc @ 52183
Installation
Disconnect the power supply, then secure the unit to prevent unintentional switching on. Only use the unit in its hori-
zontal position and ensure stable installation on a firm ground. The unit must be positioned below the water surface
level and can be placed in (submerged) or outside of the pond (dry).
Dry installation (E)
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Open the strainer casings, remove the pump, remove the controller (3) as well as the suction adapter (2), and fit the
suction and pressure line. The installation accessories (4) in the form of stepped hose connection, seals and hose
clips are part of the kit.
Connection to the water filter (B)
Plug the union nut over the stepped hose connection, fasten hose (1" - 1 1/2") on the stepped hose connection and, if
necessary, fasten with the hose clip, plug stepped hose connection into the pump outlet, tighten the union nut, then
connect the other end of the hose to the water filter.
Connection to the satellite filter (C) or skimmer (D)
Plug the union nut over the stepped hose connection, fasten the hose to the satellite filter on the stepped hose connec-
tion, insert the latter into the inlet regulator of the strainer casing, then fasten union nut.
Attention! If you operate the pump in the strainer casing when submerged, ensure that the satellite filter or
skimmer is always connected to the inlet regulator or that the inlet regulator is completely closed („0" posi-
tion)!
The power supply must be disconnected to switch off the unit.
Pos: 44 /Pumpen/Schlammsauger/Aquamax ECO/Reinigung Aquamax ECO @ 0\mod_1126270761551_121.doc @ 4033
Cleaning
Attention! Always disconnect the power supply prior to starting cleaning and maintenance work!
Remove the hoses from the unit. Press in the engagement points on both sides of the outlet opening to the water filter
and open the strainer casing, remove the pump from the strainer casing, remove the inlet regulator from its guide,
rotate the pump housing, then clean the impeller vanes using a brush.
Clean strainer casings, hose connections and inlet regulator using clear water and a brush. After cleaning, fit the unit in
the reverse order.
Pos: 45 /Pumpen/Schlammsauger/Aquamax ECO 12000-16000/Lagern Aquamax Eco 12000-16000 @ 8\mod_1218631301148_121.doc @ 49633
Storage/Over-wintering (H)
The unit is frost resistant to minus 20 °C. Should you store the unit outside of the pond, clean it thoroughly with a soft
brush and water, check it for damage, then store immersed in water. Do not immerse the power plug in the water!
Pos: 46 /Alle Produkte/Entsorgung - gem. Bestimmungen/Fachhändler @ 0\mod_1125578523312_121.doc @ 1407
Disposal
Dispose of the unit in accordance with the national legal regulations.
Pos: 47 /Pumpen/Schlammsauger/Aquamax ECO R/Störung Aquamax ECO R @ 4\mod_1160478852194_121.doc @ 27825
S
Malfunction
Malfunction
The unit does not perform its suction function
Water flow insufficient
Unit switches off after a short running period
Pos: 48 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630
8
Cause
No mains voltage
Impeller blocked/running dry
Strainer casing/satellite filter clogged
Hose blocked
Hose kinked
Excessive loss in the hose due to friction
SFC reduces the water quantity
Strainer casing clogged
Unit running dry
Remedy
Check mains voltage
Clean/check supply lines
Clean
Clean, or replace, if necessary
Check hose, and replace, if necessary
Reduce hose length to reduce frictional loss
Deactivate the SFC
Clean
Check supply line