10. Transport (Fig. 2)
The garden pump is equipped with a pull-out
transport handle (9) and wheels (6) to make it easier
to transport.
Pull out the pull-out transport handle (9) as far as it
will go.
The pump can now be pulled along with ease.
After transport, push the pull-out transport handle
(9) back in again.
The pump can also be carried by the carry handle
(10).
11. Starting up
Important!
You are allowed to start up the pump only when
it is in horizontal position.
Set up the pump on flat and firm ground.
Attach the intake line ready for use.
Plug into the mains.
Fill the pump with water at the pressure
connection.
All shut-off devices in the pressure line (spray
nozzles, valves etc.) must be fully opened when
priming so that any air in the intake line can
escape.
Depending on the suction height and the amount
of air in the intake line, priming can take anywhere
between 30 seconds and 5 minutes. If it takes
longer than this, the pump should be refilled with
water.
If the pump is removed again after use, it must
always be refilled with water whenever it is
connected up and used again.
12. Maintenance instructions
The pump is basically maintenance free. To
ensure a long service life, however, we
recommend regular checks and care.
Warning!
Before every servicing, switch off the pump
and remove the plug from the socket.
If the pump is not going to be used for a long time
or has to be removed for the winter months, rinse
it out with water, empty it completely and allow it
13:01 Uhr
Seite 9
to dry.
If there is a risk of frost, the pump must be
emptied completely.
After long stoppages, make sure the rotor turns
correctly by briefly switching the pump on and off.
If the pump becomes blocked, connect the
pressure line to the water line and remove the
intake hose. Open the water line. Switch on the
pump several times for approx. 2 seconds. Most
blockages can be removed in this way.
13. Replacing the mains cable
Warning! Disconnect the pump from the mains!
If the mains cable is defective, it must be
replaced by an electrician.