• Nominal Battery Voltage → select a voltage manually, do not choose Auto
• Charge Voltage → Enter the desired charge voltage
• Absorption Time → Enter the desired absorption time
• Float Voltage → Enter the desired float voltage
• Restart Voltage → Enter the desired restart voltage
• Auto Equalize Charge → Off
• Equalize Voltage → Enter the same value as Charge Voltage
• Equalize Duration → 10min (do not set to 0min.!)
• Temperature Compensation → Not Compensated
• Undervoltage Alarm On Value → Enter the desired voltage
• Undervoltage Alarm Relay → Enter the desired voltage
• Undervoltage Alarm Off Value → Enter the desired voltage
• Undervoltage Alarm Delay Time → Enter the desired time
The parameters indicated in
functionality.
3.3
Omnicharge Solar charger setup using the info/control display
As mentioned earlier in this document, it is advised to do all setup tasks using the Dashboard Mobile
app. There is however a possibility to do a basic setup using the info/control display of the solar
charger as well.
We will first explain the display in more detail using the image below.
In normal operating mode, you can use the SELECT button to cyclically browse through the following
screens:
• Main overview (start screen)
• Solar panel voltage
• Battery voltage
red