Tips and help
9
Tips and help
Problem
Battery symbol flas-
hes
Unit switches off
Temperature dis-
- - -
play
Temperature dis-
OL -
play -
10
Warranty and service
10.1
Warranty
10.2
Service
50
Cause
Low battery voltage
Battery empty
Temperature clamps not connec-
ted
or
Temperature value is below the
specification
Temperature value is above the
specification
Every Wöhler MR 400 fitter's aid is tested for all
functions and only leaves our factory after a de-
tailed quality check.
If used properly, the warranty period on the Wöh-
ler MR 400 fitter's aid is twelve months from the
date of sale. Excluded are batteries and damage
to the pressure sensor caused by overloading.
The warranty does not apply if repairs and modifi-
cations have been carried out on the unit by a
third party, not authorised by the manufacturer.
SERVICE is very important to us. That is why we
are of course also there for you after the warranty
period.
Solution
Change batteries
Change batteries
Connect temperature clamps
You send the meter to us, we repair it within a
few days and send it to you with our parcel
service.
Immediate help is available from our techni-
cians on the phone.