▶ Loosen and remove the front fascia of the appliance.
Fig. 11
▶ Turn around the hot water pipe.
▶ Open the side fixing parts of the hydraulic block.
Fig. 12
Tronic 4000 – 6721830066 (2021/06)
Installation (only for approved contractors)
▶ Remove the hydraulic block from the back.
Fig. 13
5.4
Water connection
NOTICE
Damages to the installation!
Damages to the water pipework.
▶ Ensure that the pipework can withstand a maximum
pressure of 10 bar and a maximum temperature of 100 °C.
NOTICE
Danger of damage to the appliance!
The existence of sand can cause a reduction in the flow rate and
its obstruction in more serious cases.
▶ Purge the water circuit before installing the appliance.
Accessories
The accessories supplied with the device must be used, as
shown in Fig. 15.
▶ Only use taps and accessories with capacity to operate in a
closed circuit (under pressure).