Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping their hands warm,
and organising workflows correctly.
Assembly
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Inserting/changing the saw blade
When fitting or changing the saw blade, wear protect-
u
ive gloves. Blades are sharp and can become hot when
used for prolonged periods of time.
Selecting the saw blade
You will find an overview of recommended saw blades at the
end of these operating instructions. Only use saw blades
with single lug shank (T shank). The saw blade should not be
longer than required for the intended cut.
Use a narrow saw blade when sawing tight curves.
Inserting the saw blade (see figure A)
Clean the shaft on the saw blade before inserting it.
u
A dirty shaft cannot be securely fixed in place.
Press the SDS lever (8) forward to the stop and hold it
down. Push the saw blade (10), with the teeth in the cutting
direction, into the saw blade receptacle (13) until it clicks
into place.
Make sure when inserting the saw blade that the back of the
saw blade is in the groove on the guide roller (9).
Check that the saw blade is seated securely. A loose
u
saw blade can fall out and lead to injuries.
Removing the saw blade (see figure B)
Push the SDS lever (8) all the way forwards and remove the
saw blade (10).
Anti-splinter guard (see figure C)
The anti-splinter guard (14) (accessory) can prevent splin-
tering of the surface while sawing wood. The anti-splinter
guard can only be used with certain saw blade types and only
at a cutting angle of 0°. When sawing with the anti-splinter
guard, the base plate (5) must not be moved to the rear for
sawing close to edges.
Push the anti-splinter guard (14) into the base plate (5)
from below.
Dust/Chip Extraction
The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
1 609 92A 862 | (05.08.2022)
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
– Provide good ventilation at the workplace.
– It is advisable to wear a P2 filter class breathing mask.
The regulations on the material being machined that apply in
the country of use must be observed.
Avoid dust accumulation at the workplace. Dust can
u
easily ignite.
Hood (see figure D)
Fit the hood (15) before you connect the power tool to the
dust extraction system.
Attach the hood (15) to the power tool so that the bracket
locks into place on the shock protection guard (11).
Remove the hood (15) when working without a dust extrac-
tion system and for mitre/bevel cuts. To do this, pull the
hood forwards off the shock protection guard (11).
Connecting the dust extraction (see figures E–F)
Fit the extraction outlet (16) in the recesses of the base
plate (5).
Ensure that the cam on the extraction outlet slots into the
corresponding recess in the power tool as shown in the
figure E.
Connect a dust extraction hose (17) (accessory) to the ex-
traction outlet (16). Connect the dust extraction hose (17)
to a dust extractor (accessory).
You will find an overview of connecting to various dust ex-
tractors at the end of these operating instructions.
For optimum dust extraction, where possible use the anti-
splinter guard (14).
Switch off the sawdust blower device when you have con-
nected the dust extraction system.
The dust extractor must be suitable for the material being
worked.
When extracting dry dust that is especially detrimental to
health or carcinogenic, use a special dust extractor.
Operation
Products that are only sold in AUS and NZ: Use a resid-
u
ual current device (RCD) with a nominal residual current
of 30 mA or less.
Operating modes
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Pendulum action settings
The pendulum action can be adjusted using four different
settings, allowing the cutting speed, cutting capacity and the
cut itself to be optimally adapted to the material that you
want to cut.
You can also adjust the pendulum action during operation
using the adjusting lever (7).
Level 0
No pendulum action