Operating and assembly instructions S-HP
EN
Note!
The eye bolt on the motor must not be used to lift
the entire blower. This is used if the motor needs
to be (dis-)assembled.
Note!
Devices with frequency converters for built-on
operation (FUK devices):
It is neither allowed to use the frequency con-
verter to lift up the device nor to use it as climb-
ing help!
2.2 Storage
• Ensure that the air intake connection and pressure connec-
tion are closed.
• Store the blower
-> in its original packaging if possible
-> in a closed room
-> in a dry, dust-free and vibration-free area.
• Storage temperature range from -20°C to +60°C
• After a storage period of 6 months, the blower bearings
and/or motor bearings should be checked before they are
mounted in the blower.
• Devices may be stored for a maximum of 2 years.
3 INFORMATION ON COMMISSIONING
THE MACHINE

3.1 Basic information

12
• Prior to the fi rst start-up and before any other start-up, the
proper operating status of the unit must be inspected. Units
that, for example, are found to be defective upon delivery
or during installation, must be examined by qualifi ed techni-
cians.
• Installation, assembly and operation must only be performed
by properly trained and qualifi ed specialists. Operation fol-
lowing incorrect installation, maintenance or unapproved
replacement of components constitutes non-designated use
and renders the warranty void. The resultant risk shall be
borne solely by the customer or owner.

3.2 Installation and assembly

• Protect the blower from the weather and install it in a
horizontal position, see also 1.1. For outdoor use, protec-
tion from the weather must generally be provided that
fulfi ls the requirements listed in 1.1 Intended Use and
protects the blower from the infl uences of the weather.
• Do not subject the blower subsequently to vibration or
impact loads during operation. Permissible vibrational load
on blower: refer to ISO 14694, BV-3.
АО "БЕРГАБ" Тел./факс: (495)727-22-72 catalog@elektror.ru
Measurement at the fl ange bearing shield, preferably
near the bearing
Maximum permissible vibration speed
(Limit values according to ISO 14694:2003 (E),
category BV-3)
Rigidly mounted
[mm/s]
Eff ective value
[r.m.s.]
At installation
Start-up
4.5
Alarm
7.1
Shut-down
9.0
• The enclosed rubber buff ers have to used.
• The rubber buff ers must not be subjected to any shear
forces or tension.
• Standard blowers with base or console:
Bolt securely to a level and fi rm surface at the place of
use, making sure that the surface has adequate load-
bearing capacity and avoiding vibration transmission or
vibrational load.
• Other standards and regulations must be observed
depending on the application.
• Blower feet and consoles must be designed only for the
respective blower's own weight.
• Cover the open air intake and discharge with protective
grilles according to DIN EN ISO 13857.
• Ensure that the motor has adequate ventilation.
Permitted ambient temperatures with:
Note!
The rated effi ciencies and the effi ciency classes
of the motors are given as per IEC 60034-2-1 for
operation at an ambient temperature of 25°C.
As per IEC 60038 Elektror motors are generally
designed for an extended voltage range of ±10%.
However, the stated effi ciency relates to the rated
voltage, i.e., the extended tolerance is not taken
into account.
• Ambient temperature -20°C to +40°C
• Voltage tolerance ±5% (For exceptions, see „4.2 Fre-
quency converter operation")
• The drive motor ventilation system must not be aff ected
by the installation situation.
www.elektror.com
= Measuring point
= Measuring
direction
Flexibly mounted
[mm/s]
Eff ective value
[r.m.s.]
6.3
11.8
12.5

Werbung