Herunterladen Inhalt Inhalt Diese Seite drucken

Self-Diagnosis; 13. Decommissioning; Temporary Shutdown; Change Of Location - Bosch WBE 4100 Originalbetriebsanleitung

Radauswuchtmaschine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
42 | WBE 4100 | Decommissioning
12.4

Self-diagnosis

1. Press and hold the <MENU> key.
2. As soon as
appears in the left-hand display,
t5t
release the <MENU> key.
3. Press the <mm/inch> key within 1.5 seconds.
i
Press the <MENU> key to switch from one function
to the other.
"
The following information is displayed:
R
Pick-up voltage
$
The display shows
R
Angular position of shaft
$
The display shows
R
Shaft speed
$
The display shows
R
Character readout
R
Wheel guard microswitch input readout
$
The display shows
R
Start counter
$
The display shows
R
Display test
$
The display shows
R
Calibration data
$
The display shows
R
Instantaneous wheel balancing
$
The display shows
Proceed as follows to check correct operation of the
pick-ups:
1. Clamp a balanced test wheel in position.
2. Attach a test weight (e.g. 100 g Pb or 60 g Zn).
3. Perform reference measurement.
On completion of the reference measurement
R
The voltage value of the inner pick-up must be lower
than that of the outer pick-up.
R
The ratio between the outer and inner pick-up value
must be between 1.2 and 1.8.
R
The phase difference must be 180° ± 1°.
|
1 695 656 133
2011-02-18
M5r
EnC
5P
InP
Cnt
LEd
tAA
rEL

13. Decommissioning

13.1

Temporary shutdown

In the event of lengthy periods of non-use:
Unplug the electrical connection.
13.2

Change of location

If the WBE 4100 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
The WBE 4100 is only ever to be transported in the
original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
Bolt the WBE 4100 back onto the pallet.
13.3

Disposal and scrapping

13.3.1

Substances hazardous to water

!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
13.3.2

WBE 4100 and accessories

1. Disconnect the WBE 4100 from the mains and detach
the power cord.
2. Dismantle the WBE 4100 and sort out and dispose of
the different materials in accordance with the ap-
plicable regulations.
The WBE 4100 is subject to the European direc-
tive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of the WBE 4100 prevents
environmental pollution and possible health
hazards.
Robert Bosch GmbH

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis