4. Installation

Tap
Spacer
S/S washer
Spider clamp
Fixing nut
B

Installing the tap

Note: The tap must not be installed more than 900 mm above the base of the
undersink unit. Failure to do this may result in poor water delivery.
Note: Under no circumstances should the tap be twisted after the installation is
complete.
1. Make sure that the tap location will allow water from the tap to fall into a sink or
other basin fitted with a drain to drain away.
2. Cut a 35 mm diameter hole in the worktop / sink at the place where the tap is to be
installed.
3. Push the black spacer on to the tap from underneath and ensure it remains in
position. A light smearing of silicone sealant on the underside of the spacer will
ensure a watertight fit.
4. Pass the hoses down through the 35 mm hole in the worktop / sink and locate the
tap head on its mounting location.
5. From the underside, push the stainless steel washer over the hoses and then
push the spider clamp on to the threaded rod of the tap fitting. Secure the spider
clamp with the fastening nut. Check the tap head is in the correct position before
tightening up the nut.

Installing the undersink unit

Note: An air gap of at least 50 mm at the left and right of the unit must be
provided for adequate ventilation. If the unit is to be operated inside a cupboard,
the supplied silicone buffers should be affixed to the inside edge of the cupboard
doors and the ventilation grills should be installed.
The positions of the cut outs 'A' and 'B' shown in the drawing are to be regarded as a
recommendation and may vary depending on the installation environment.
A
B
A
21
The cut outs A and B can be covered with
the provided ventilation grilles.
285.00
There must be a distance from at least
10 cm between the cut outs A and B, to
avoid a thermal short circuit.
314.00
326.00