5.6.2 Fire extinguishes
The fire is smoldering or dying out.
Is the combustion air regulator open?
Is the flue gas damper open?
Is the fire door closed?
Is the fuel quality okay?
Is the fuel quantity correct?
Is the delivery pressure in the chimney high
enough?
Is the seal on the fire door intact?
Is the weather unfavorable?
Is there too much ash in the firebox?
Is an exhaust fan operating near the unit?
5.6.3 Rapid Burnup
The fire burns erratically or very quickly.
Is the flue gas damper open?
Is the fire door closed?
Is the fuel quality ok?
Is the fuel quantity correct?
Is the delivery pressure in the chimney too high?
Is the seal on the fire door intact?
5.6.4 Heavy Soot Formation
A thick layer of soot quickly forms on the ceramic glass.
Is the flue gas damper open?
Is the fuel quality okay?
Is the fuel quantity correct?
Is the delivery pressure in the chimney high
enough?
Is the seal on the fire door intact?
5.6.5 Smoke in the Installation Room
Flue gases escape into the installation room without adding fuel.
Is the flue pipe between the space heater and the
chimney tight?
Is the fire door open?
Is the delivery pressure in the chimney too high?
Is there negative pressure in the room?
Is the seal on the fire door intact?

5.6.6 Odor Load in the Installation Room

Unusual odors pollute the climate in the installation room.
Is the safety distance in the radiation area main-
tained?
Is an object placed too close to a hot surface?
Is an object or house dust visible in the cavity below
the cladding above?
Instruction Manual
Open the combustion air regulator
Open flue gas damper
Close the fire door completely
Use good quality fuel
Use correct amount of fuel
Have the delivery pressure checked with a meas-
uring device
Have the gasket replaced
-
Clean the firebox
Switch off the exhaust fan temporarily
Close the flue gas flap by 1/3.
Close the fire door completely
Use good quality fuel
Use correct amount of fuel
Have the delivery pressure checked with a meas-
uring device
Have the seal replaced
Open the flue gas flap completely
Use good fuel quality
Use correct quantity of fuel
Have the delivery pressure checked with a meas-
uring device
Have the seal replaced
Have connections sealed
Close the fire door and lock it.
Have the delivery pressure checked with a meas-
uring device
Open the window in the room.
Have the seal replaced
Maintaining the safety distance
Remove object
Remove object or house dust when the unit has
cooled down.