Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
Pinspot.
Always fix the Pinspot with an appropriate safety-rope.
The maximum ambient temperature T
Operate the device only after having become familiar with its functions. Do not permit operation by persons
not qualified for operating the device. Most damages are the result of unprofessional operation!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.

INSTALLATION

Installing/Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
Please follow the lamp manufacturer's notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one 6 V/30 W PAR-36 lamp.
During the operation, the lamp reaches temperatures of up to 130° C.
Procedure:
Step 1: Please remove the fixation ring by pressing it together.
Step 2: If replacing the lamp, remove the old lamp from the pinspot and loosen the wires.
Step 3: Loosen the screws on the new 6 V/30W PAR-36 lamp with an appropriate screwdriver.
Step 4: Connect the wires with the lamp using an appropriate screwdriver.
Step 5: Tighten the screws.
Step 6: Insert the lamp in the housing.
Step 7: Fix the lamp with the fixation ring.
Please note: Lighting units should be fitted with splinter protection. If defective, please dispose of the
unusable lamp in accordance with the current legal regulations.
must never be exceeded.
a
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
17/23
00056306.DOC, Version 2.1