Procedure:
Step 1: Make sure that the device is turned off, disconnected from the mains and completely cooled
down.
Step 2: Unscrew the fixation screws of the protective grid.
Step 3: Remove the protective grid.
Step 4: If necessary, remove the old illuminant from the socket and carefully insert the new illuminant.
Avoid touching the glass blub bare-handed.
Step 5: Replace the protective grid and tighten the screws.
Step 6: Only reconnect the device to the mains after the front cover has been closed and securely fixed.

INSTALLATION

WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing down. Make sure
that the device is installed securely and cannot fall down. The installation must be carried out by
a specialist who is familiar with the hazards and the relevant regulations.
The device may be placed on the floor or fastened to a truss or similar rigging structure. The device must
never be fixed swinging freely in the room.
1
The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
2
Block access below the work area and work from a stable platform when installing the device.
3
Use rigging hardware that is compatible with the structure and capable of bearing the weight of the
device. Please refer to the "Accessories" section for a list of suitable rigging hardware.
4
Secure the device with a safety bond or other secondary attachment. This secondary safety attachment
must be sufficiently dimensioned in accordance with the latest industrial safety regulations and
constructed in a way that no part of the installation can fall down if the main attachment fails. An
appropriate eyelet is mounted on the device for fixation of the safety rope. Fasten the safety rope in such
a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm.
5
To align the device, release the fixation screws at the mounting bracket, adjust the desired inclination
angle and tighten the fixation screws.
6
After installation, the device requires inspections periodically to prevent the possibility of corrosion,
deformation and looseness.

OPERATION

Connect the mains cable to a grounded mains socket and switch on the device. The lamp needs about 3-4
minutes warm-up time until it reaches full lighting output.

CLEANING AND MAINTENANCE

The outside of the device should be cleaned periodically to remove contaminants such as dust etc.
1
Disconnect the device from power and allow it to cool before cleaning.
2
Clean the surface with a soft lint-free and moistened cloth. Never use alcohol or solvents as these may
damage the surface. Make sure that no liquids can enter the device.
3
The device must be dry before reapplying power.
There are no serviceable parts inside. Do not open the housing. Do not try to repair the device by yourself as
this may result in damage. Maintenance and service operations are only to be carried out by authorized
dealers. Should you need any spare parts, please use genuine parts. Should you have further questions,
please contact your dealer.