Aufladesteuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replacing an existing ELFAMATIC V 2100
The device must be connected as shown in the circuit
diagram.
Removal
To remove the controller, release the top part from the
base (as described above) and disconnect the connecting
cables.
Then release the base from the rail as shown in the
illustration opposite.

2.3.2 Electrical connection

The ELFAMATIC V 3000 must be connected as shown in the
connection diagram on page 17.
It is especially important to note the following points:
1. If only one night-time charging time is available, LF can
also be connected to terminal L (if point 5 is satisfied).
2. Z1/Z2 can be loaded up to max. 300 W.
3. The ELFAMATIC V 3000 and the group control unit
ELFAMATIC G 3000 are also suitable for "single-wire
control".
The "clocked" outer conductor is connected to
terminal Z1/A1.
4. Phase coincidence between L and LF and between the
outer conductors for ELFAMATIC V 3000 and
ELFAMATIC G 3000 as well as a specific phase sequence
are not necessary.
5. By installing a "summer switch" in the supply cable for
"L" and fitting the charging contactors, the charging
controller and the charging contactors can be switched
off outside the heating period.
6. The ED system can be set using DIP switches 1 and 2
inside the top part of the housing.
40% ED
70% ED
80%ED
Electronic
charging
controller
7. Setting the E2 step
DIP switch 3 allows selection of a minimum charge of
15 % if the charging start E2 is underranged.
DIP 1
DIP 2
off
off
off
on
on
off
on
on
For the Fitter
Spare fuse
DIP 1
DIP 2
DIP 3
15