For the Fitter

2. Installation instructions

2.1 Regulations and specifications

Installation and electrical connection must be performed by a specialist technician in compliance
with these installation instructions.
All electrical connection and installation work must be performed in accordance with the VDE
regulations (0100), specifications from the responsible power supply company and the relevant
national and regional regulations.
See the information and materials enclosed in the device packaging.
Observe the information on the device rating plate.
The specified voltage must be identical to the mains voltage.

2.2 Technical specifications

Supply voltage
Power consumption
ED system
Terminal cross-section
Switching capacity
Fuse
Ambient temperature range
Degree of protection
Safety class
DIN atmospheric sensor:
Resistance values
Degree of protection
Safety class
Ambient temperature range
Connecting cable
Dimensions

2.3 Installation

2.3.1 Controller

The ELFAMATIC V 3000 must be fitted in the bottom row of a distribution board, whereby a gap of
one SI circuit-breaker width must be provided at the sides.
Shock protection to safety class II is provided if the ELFAMATIC V 3000 is installed in
a small distribution board to DIN or
a distribution board to DIN
The ELFAMATIC V 3000 consists of a base with terminals for
rail mounting as well as the plug-in housing with the
electronic components.
The top part of the housing is removed from the base by
releasing the lower housing catch using a screwdriver and
then pulling off the top part.
The base must be de-energised before the top part of
the housing is mounted.
14
200–230 V +10 % / - 15% AC 50/60 Hz
3.0 W
40 / 70 / 80 %, or "EL"
Max. 2.5 mm
2
300 W resistive load (Triac)
T 1.6 L 250 V
0 °C to +50 °C
IP 20 (after installation)
II (total insulation)
See page 16
IP 54
II
–40 °C to +50 °C
2 x 0.75 mm², approx. 1.4 m long
(cable length between sensor and ELFAMATIC: max. 30 m
– shielded cables required for longer lengths)
∅ 11.5 x 35 mm
-10
-5
10
15
-15
0
5
20
-20
+5
-25
+11
0
25
E1
E2
40
60
ELFAMATIC V 3000
20
80
ED
RA
0
100