Maintenance and Care

 To ensure proper functionality and a long lifetime, diligent lubrication and
maintenance is essential.
 For operating pneumatic tools clean air is required. Corrosion residues, dust
and dirt from the pneumatic pipes reduce the efficiency of the tool and will
cause technical problems. An upstream maintenance unit consisting of filter,
pressure regulator valve and lubricating equipment removes moisture and dirt
from the air, controls the working pressure and supplies the tool perfectly with
lubricating oil.
 If necessary clean the air impact wrench with a moist cloth.
 Do not use abrasive or aggressive chemicals as benzene or thinner, which
may dissolve plastic parts.
 Do not allow liquids to enter the tool and never immerse it into liquids. Water in
the compressed air inlet can damage the machine. Therefore it is recommend-
ed to drain the air lines and the compressor regularly! Also clean the air filters
on a regular basis.

Lubrication

Pneumatic tools always have to be lubricated sufficiently. This is done continu-
ously and safest by using an oil-fog lubricator. If the oiler is mounted centrally at
the compressor or mounted firmly at the end of the compressed-air pipe installa-
tion, only use a hose with a length of max. 10 m. If the hose is longer, the
nebulisation disappears in the air. The oil floats inside the hose and does not
arrive at the air tool.
If you intend to use a supplied mini oil-fog lubricator, install it directly on the
compressed air connection (5) of the air impact wrench. Connect the quick
coupling adaptor to the other end of the mini oil-fog lubricator.

Oiler Setting

Hose up to 5 m
Hose up to 10 m
If you do not intend to use an oiler, please put a few drops of oil into the com-
pressed air connection before every machine usage. Lubricate the air tool once
more after use, especially if you do not operate the unit for a long time. Further
maintenance work is not necessary.
Operation
every 2 min.
once a min.
13