7.3.
Maintenance and inspection table
Interval
Parts to be inspected
8 hrs
Safety devices
Fluff filter
Make sure to reinsert the fluff filter.
Risk of injury!
Maintenance unit
40 hrs
compressed air
Entire machine
160 hrs.
12 month
If necessary
23.05.2017
INSPECTION AND MAINTENANCE PLAN
Main switch
Switch and switch
fixtures
Manometer pressing
pressure
Pneumatic valves
Cylinders
Steam valves
Suction valves
Hoses and screw
connections
Bucks
Guideways
Impeller
Covers
Pressing surface head
buck
Kragen- und Manschettenpresse 8905
Work to be carried out
Functional inspection
Cleaning
Visual inspection
Cleaning
Functional inspection
Visual inspection
Leak test
cleaning
greasing
Visual inspection for
abrasion
Check guiding
clearance
Cleaning
Visual inspection
Clean the pressing
surfaces
8905 Collar and Cuff Press
Remarks
see chapter 2.3 BUILT-IN
SAFETY SYSTEMS
Drain off water/oil
Pressure range: 6 bar
1 x annually clean and
replace dirty air filter if
necessary
Wipe with a clean, lint-free
cloth.
Check and replace if
necessary.
Pressure range: 0 – 6 bar
Check and replace if
necessary.
Should leaks be
discovered on the bucks,
the VEIT service
department has to be
informed immediately.
Should irregularities in the
guiding system occur, the
VEIT service department
has to be informed
immediately.
Wipe with a clean, lint-free
cloth.
Cleaning, washing and
replace if necessary.
If necessary, clean
chromed pressing
surfaces with grinding
paste (KC00460).
37