Maintenance and troubleshooting
instructions
For maintenance and troubleshooting observe the
following general rules:
– Only suitably qualified staff may perform this
work on the device.
– The device must be switched off and the pow-
er plug must be disconnected from the mains
socket.
13.1

Operating conditions

The device is intended for mobile or stationary use
indoors, on construction sites, in garages and
storage spaces / rooms. The device operates effi-
ciently:
– Within a temperature range from 5 °C to
+35 °C and at 40 % to 100 % relative humidity
– In closed rooms where there is as little air ex-
change as possible
– If it is placed as centrally as possible in the
room and
– the dry air is discharged towards the wet part
of the room
NOTICE
Optimal moisture extraction and room
temperature
In smaller rooms, the room temperature may be
significantly increased by the operation of the
condensation dryer. Room temperatures between
20°C and 27 °C offer ideal conditions for oper-
ating the device.
In addition, comply with the following conditions
and safety instructions:
– Always handle the device with care. Never
drop the device, do not throw it or transport it
unsecured.
EN
– The device must be installed upright and sta-
ble.
– The air must be able to circulate freely (keep a
free space of at least one metre around the
device).
We recommend operating the device in con-
junction with fans to ensure maximum air cir-
culation.
– Do not cover the device during operation.
– Ensure that the condensate can always run off
safely into a drain or a suitable vessel. Vessels
used for collecting the condensate must be
emptied regularly.
– Never drink any condensate that may accumu-
late, there is a danger of infection.
– The device must not be operated in puddles or
in stagnant water. If the device or the connec-
tion cable gets wet then it must be dried thor-
oughly before the device may be operated.
– Make sure that the device does not suck in
any oil, grease or other contaminant.
– Only use the device with a clean air filter.
– The mains voltage must correspond to the de-
tails on the rating plate.
– Extension cables must be selected according
to the performance data on the rating plate, in
order to prevent overload.
– The socket used must be earthed or protected
with a current operated earth leakage circuit
breaker when installed indoors.
– People under the influence of alcohol, drugs or
medication must not operate or maintain the
device.
– Only original spare parts or parts approved by
the manufacturer may be used.
Under inadmissible operating conditions, the op-
erational safety and the performance of the device
may not be sufficiently ensured. Inadmissible op-
erating conditions must therefore be avoided at all
times.