5.8

Replacing the battery

WARNING
Risk of explosion
To reduce the risk of ignition of a flammable or explosive atmosphere, observe
the following:
► Do not open the gas detector in explosion-hazard areas.
► Only the battery types specified in the technical data must be used.
► Do not charge or replace the battery underground or in explosion-hazard
areas.
NOTICE
Damage to the gas detector
The power pack for the X-am 2500/5000/5100/5600 gas detectors (order
no. 8318704) must not be used for the X-am 2800, as the seal cannot ensure
the IP protection for the X-am 2800 and was not approved together with the X-
am 2800.
► Only use the power pack (order no. 3703887) for the X-am 2800.
1. Switch off the gas detector.
2. Undo the screw on the power pack.
3. Remove and replace the NiMH power pack T4 (type HBT 0010).
4. Insert the power pack into the gas detector and tighten the screw, the gas
detector switches on automatically.
5.9

Cleaning

The gas detector does not require any special care.
If it is heavily soiled, wash off the gas detector with cold water, using a sponge if
necessary. Dry the gas detector with a cloth.
NOTICE
Damage to the gas detector!
Harsh cleaning utensils (e.g. brushes), detergents and solvents can destroy the
dust and water filters.
► Only clean the gas detector with cold water and, where necessary, a sponge.
For information on suitable cleaning agents and disinfectants and their
specifications, see document 9100081 at www.draeger.com/IFU.
®
X-am
2800
|
Maintenance
en