6.3

Alarm settings (factory setting)

Definitions:
Pre-acknowledgement: If the alarm condition is acknowledged (by pressing the
OK button), the acoustic alarm and the vibration are switched off. The alarm is
only completely reset (LED and display) once the alarm condition no longer
exists.
Acknowledgement: If an A1 alarm condition that no longer exists is
acknowledged (by pressing the OK button), all alarm elements are reset.
If the A2 and A1 alarms are configured so that they can be acknowledged, the
pre-acknowledgement or acknowledgement of the A2 alarm pre-acknowledges
the A1 alarm, or completely acknowledges this alarm if the alarm condition no
longer exists.
Explanation of the symbols:
: Feature activated
: Pre-acknowledgement
Alarms/events
A1 ↑ (increas-
ing)
A2 ↑ (increas-
ing)
A1 ↓ (decreas-
ing)
A2 ↓ (decreas-
ing)
1)2)
STEL
3)
TWA
4)
Error
Battery pre-
5)
alarm
®
X-am
2800
Presen-
tation in
the dis-
play
Latching
A1
-
A2
A1
-
A2
STEL
TWA
-
-
Acknowl
edge-
LEDs
able
-
-
-
-
|
Device settings
Vibra-
Horn
tion
en