36 | SCT / CCT / EL | Checking standard components
4
4
2
2
3
2
3
2
Abb. 19: Test boards 1 and 2 aligned with the 0-point
1 Reference laser
2 Laser beam of reference laser
3 Test board 1
4 Test board 2
8. Remove the reference laser.
9. Fasten the P-Assist S5 (Abb. 20, item 1) to laser
mount A on the L -bracket and rotate counterclockwi-
se as far as possible.
 The laser beam (Abb. 20, item 2) of the P-Assist
S5 marks both test boards.
|
1 690 386 058
2018-01-30
2
1
X2
4
4
2
2
3
2
3
2
X1
Abb. 20: Laser beam of the P-Assist S5 on test boards 1 and 2
1 P-Assist S5
2 Laser beam of the P-Assist S5
3 Test board 1
4 Test board 2
X1 Distance between the 0-point on test board 1 and the laser
beam of the P-Assist S5
X2 Distance between the 0-point on test board 2 and the laser
beam of the P-Assist S5
10. Measure the distance X1 (Abb. 20, item X1) between
the 0-point on test board 1 and the laser line of the
P-Assist S5.
11. Measure the distance X2 (Abb. 20, item X2) between
the 0-point on test board 2 and the laser line of the
P-Assist S5.
12. Add the distances X1 and X2.
 The sum of the distances X1 and X2 is the test re-
sult.
!
The test result must not be greater than 5.3 mm.
Measure in case of impermissible observational error
Replace the P-Assist S5.