Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch SCT Serie Prüfbuch Seite 28

Kalibrier- und justiervorrichtungen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

en
en
28 | SCT / CCT / EL | User instructions
2.1.2
Test board 1 690 382 354
1
Abb. 3:
Test board 1 690 382 354
1 Zero point on scale
2.1.3
Laser module 1 690 381 124
Abb. 4:
Laser module 1 690 381 124
i
The customer's laser module is identified as "P-
Assist S5" in the following. The Bosch Customer Ser-
vice laser module is identified as "reference laser" in
the following. The reference laser is needed to verify
the functionality of the P-Assist S5.
2.2
Test requirements
To test an SCT / CCT / EL, it is necessary to have a free
wall on which to fasten the test boards 1 690 382 354
by means of double-sided adhesive tape. If a free wall is
not available, a different surface can be used, e. g. the
column of a lift.
|
1 690 386 058
2018-01-30
2.3
Definition of the angle being checked
1
Abb. 5:
Test angle
1 Yaw angle
2 Roll angle
3 Pitch angle
2.4
Requirements
Setting
Pitch angle
Roll angle
Rotation around vertical axis for laser mo-
dule
Alignment of the measurement boards
Lateral positioning of the test boards
Height adjustment
Accuracy of the height adjustment
Yaw angle
Tab. 1:
SCT product requirements
2
3
Specification
+/- 0.5°
+/- 0.3°
+/- 0.15°
+/- 1.5 mm
+/- 4 mm
+/- 800 - 1500 mm
+/- 5 mm
+/- 0.2°
Robert Bosch GmbH