10 Annex

10.1 Firmware Updates

10.1.1 Updates from Firmware Version AB -102
• Automatical correction of single bit errors in RAM
• Update XQR controller version V410 → V412
New monitoring function of mechanical gun defect.
o
New monitoring function of oscillating current.
o
New schedule aborted error messages contact monitoring
o
3mOhm and data inconsistency (KSR-reference).
Reweld now in UI-Mode, measured or controlled.
o
Support of commissioning functions STC TEACH and training
o
mode (details refer to Tab1. Required and supplementary
documentation, BOS6000 Online Help).
PSF evaluation for operating mode aluminium is completed.
o
10.1.2 Updates from Firmware Version AC -103
• Driver update for ProfiNet-Module V2.x.
10.1.3 Updates from Firmware Version AD -104
• Update XQR controller version V412 → V413
Versioning of adaptive controller and monitoring.
o
Display of version number and patch number.
Monitoring function „mechanical gun defect" and „swinging
o
current" can be parameterized (electrode parameter).
New monitoring function „electrode pick up" in operation mode
o
ALUMINIUM.
Toleranceband for „Test gun resistance" (Gun resistance
o
change) can be programmed in absolute values (in µOhm).
Reference curves identifiation (origin of the reference curve)
o
are recorded in the weld current log.
• The both discrete inputs I17 and I18 are retransmitted to the serial outputs O59
(4.11) and O60 (4.12).
10.1.4 Updates from Firmware-Version AE-105
• Update XQR controller version V413 → V417.05
Adjustment coefficients for Q factors (UIP,FQF, PSF) added.
o
Automatic reweld possible if violation of absolute tolerance
o
band of the Q factors occurs.
Force measurement circuit test extended. Test is performed via
o
the tolerance band.
Revision of the resistance contact threshold calculation.
o
"Hot Staking" operating mode connection with stepper.
o
New "thin sheet with stepper" connection.
o
Reference value for heat value loaded during the automatic gun
o
resistance calibration (input bit).
Calculation of time prolongation for ALU adapted.
o