ErrorID (hex) Name
0
1
B0070001
0
1
B0070002
0
1
B0070003
0
1
B0070004
0
1
B0070005
0
1
B0070006
0
1
B0070009
Fehlernummern nach IEC 61131-3 für OPC UA
0
1
002D0000
0
1
002E0000
0
1
002F0000
0
1
00300000
0
1
00960000
0
1
00A20000
0
1
00A30000
0
1
00A50000
0
1
00A60000
0
1
00A70000
0
1
00A80000
0
1
00A90000
0
1
00AA0000
0
1
00BA0000
0
1
406C0000
0
1
408F0000
0
1
40900000
0
1
40910000
0
1
40920000
0
1
40930000
0
1
40940000
0
1
40950000
CP 443-1 OPC UA
Betriebsanleitung, 01/2017, C79000-G8900-C427-02
GoodSubscription
Transferred
GoodCompletes
Asynchronously
GoodOverload
GoodClamped
GoodLocalOverride
GoodEntryInserted
GoodEntryReplaced
GoodNoData
GoodMoreData
GoodCommunicationEvent
GoodShutdownEvent
GoodCallAgain
GoodNonCriticalTimeout
GoodResultsMayBe
Incomplete
UncertainReferenceOutOf
Server
UncertainNoCommunication
LastUsableValue
UncertainLastUsableValue
UncertainSubstituteValue
UncertainInitialValue
UncertainSensorNotAccurate The value is at one of the sensor limits.
UncertainEngineeringUnits
Exceeded
UncertainSubNormal
Programmierung der OPC UA-Client-Bausteine
Bedeutung
Falsches Datenpaket in UA_WriteList
Die Länge der zu schreibenden Daten überschreitet das
Maximum.
Ungültiger Bereich von IndexRangeCount
Ungültiger IndexRange. StartIndex darf nicht größer sein als
EndIndex und EndIndex darf nicht größer sein als die Array-
Länge.
Ungültige AttributeID
Der Datenbereich ist außerhalb des zugelassenen Bereichs.
Ungültiges Zeichen im String
The subscription was transferred to another session.
The processing will complete asynchronously.
Sampling has slowed down due to resource limitations.
The value written was accepted but was clamped.
The value has been overridden.
The data or event was successfully inserted into the historical
database.
The data or event field was successfully replaced in the his-
torical database.
No data exists for the requested time range or event filter.
The data or event field was successfully replaced in the his-
torical database.
The communication layer has raised an event.
The system is shutting down.
The operation is not finished and needs to be called again.
A non-critical timeout occurred.
The server should have followed a reference to a node in a
remote server but did not. The result set may be incomplete.
One of the references to follow in the relative path references
to a node in the address space in another server.
Communication to the data source has failed. The variable
value is the last value that had a good quality.
Whatever was updating this value has stopped doing so.
The value is an operational value that was manually overwrit-
ten.
The value is an initial value for a variable that normally re-
ceives its value from another variable.
The value is outside of the range of values defined for this
parameter.
The value is derived from multiple sources and has less than
the required number of Good sources.