1. Prior to assembling the stove
All our products are tested according to the latest
European requirements and also to the Norwegian
SINTEF standard, which includes particle tests.
Several European countries however have individual
rules for installation of inserts, stoves and fireplaces.
The client is entirely responsible for the fulfilling of
these local rules concerning the installation in his
region/country. Nordpeis (Northstar) is not responsible
regarding correct installation. You should check local
regulations concerning: distance from firebox to
combustible/flammable materials, insulation materials/
requirements between stove and back wall, size
of floor plates in front of stove if required, fluepipe
connection between stove and chimney and insulation
requirements if fluepipe goes through inflammable
wall such as a wooden wall.
Chimney Draught
Compared with older models, the clean burning stoves
of today put significantly higher demands on the
chimney. Even the best stove will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature,
air supply as well as the height and inner diameter
of the chimney. The diameter of the chimney should
never be less than that of the flue/chimney collar. At
nominal effect there should be a negative pressure of
14 to 25 Pascal.
The draught increases when:
The chimney becomes warmer than the outside air
The active length of the chimney is increased (over
the hearth)
Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the
fireplace, as the chimney does not heat up well
enough. If possible, insert a smaller chimney
pipe. Draught that is too strong can also be
controlled with a damper. If necessary, contact a
chimney sweeper.
For your own safety, comply with the assembly
instructions. All safety distances are minimum
distances. Installation of the insert must comply
with the rules and regulations of the country where
installed. Nordpeis AS is not responsible for wrongly
assembled inserts.
The illustration indicates the approximate center height
of the hole for the flue. Distortions in floors and walls
may influence the height. Place the stove for accurate
position and height of the flue/chimney connection.
We accept no liability for typographical errors and
changes.
10

2. Technical Information

The stoves from Nordpeis have secondary
combustion and are clean burning. The combustion
takes place in two phases: first the wood burns and
then the gases from the fumes are lit by the hot air.
This ensures that these new stoves have minimal
emissions of soot particles and unburnt gases (such
as CO) and are thus better for the environment. Clean
burning stoves require a small amount of wood in
order to obtain a good heat output. Use exclusively
clean and dry wood. We recommend seasoned
hardwood with a maximum moisture content of 20%.
Product
Material:
Weight Stove
Surface treatment door/
doorframe:
Fuel:
Operating range:
Nominal heat output kW]
Efficiency
CO @13% O2
Flue gas temperature (
Draught system:
Combustion system:
Flue outlet:
Flue:
Possible to connect steel
chimney:

3. Distance to Combustible Material

Ensure that the safety distances are respected
(FIG 1).
The distance from the front of the stove to furniture
needs to be of at least 1 metre. When connecting
a steel chimney to the top outlet use the security
distances required from the manufacturer.
GB
Orion
Cast iron
72 kg
Heat resistant varnish
Wood logs, 30 cm
1-6 kW
4,9
> 65 %
<1500 mg/m³
208
°C)
Air vent control
Secondary
combustion (clean
burning)
Top, lateral and rear
Outer Ø 125 mm
Yes

Werbung