Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Disposal Information - Samoa 383 400 Bedienungsanleitung Und Ersatzteile

Vorschau ausblenden Andere Handbücher für 383 400:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
BYPASS MODE
Under these mode, a "trip" meter is available (Fig. 13) in
order to simplify the execution of individual dispenses. To
do this, just press and hold the "power" button until the
displayed quantity changes to zero (9). From now on, the
dispensed volume will increase from zero ("trip" meter).
The "total" meter will now be displayed on the bottom
right corner of the screen (10), next to the units.
CAUTION:
In by-pass mode the amount of fluid dispensed is not
registered in the monitoring system.

TECHNICAL SPECIFICATIONS

Unit compatibility
Batteries
Connectivity
Temperature operation range -10 ºC a 60 ºC
Weight
Display
TROUBLESHOOTING
Symptom
Lack of connection
The screen does not turn on
The unit is configured but it does
not work

DISPOSAL INFORMATION

6
838 842 R. 05/23
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
SAMOA 1/2" oil control gun
Samoa fluid handle
4 x AA / LR6
Bluetooth LE
420 g (0.92 lb)
Dot matrix 128x64 with
backlight
Possible cause
Unit not configured
Wrong batteries assembly
Batteries run out of energy
Wrong pairing
The symbol above means that according to local laws and regulations your product and/or its
battery must be disposed of separately from household waste. When this product reaches its end of
life, take it to a collection point designated by local authorities. The separate collection and recycling
of your product and/or its battery at the time of disposal will help conserve natural resources and
ensure that it is recycled in a manner that protects human health and the environment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference That may cause undesired operation.
Solution
Consult pairing instructions
Check batteries polarity
Replace batteries
Check that the unit is paired with the
correct hose reel
10
Fig. 13
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis