0 3 . 1 1 Thur
Fa ir 2 2 ℃
Hum idity
6 8%
Product Overview
Vue d'ensemble du produit
This series of thermostat has Floor Heating, Fan Coil, and Integrated version,
Ce thermostat est disponible en plusieurs versions pour répondre à toutes les
configurations : Chauffage au sol, ventilation et intégré.
meeting the requirements of different scenarios.
Version
S ystem mode
Modèle
Version
System mode
716
71 6S
Chauffage
Chauffage
Chauffage au sol
703
Chauffage au sol
au sol
au sol
703S
723
723S
743
853
Heating /Cooling /
Fan Coi
Ventilation
Heating /Cooling /
853S
Fan Coil
Ventilation
863
863S
Fan-Coil with
Integrated
Floor-Heating
Fan-Coil with
air condition system
963
Integrated
Floor-Heating
963S
air condition system
Symbols on display
Сlock
Date/week
Outdoor temp.
Outdoor humidity
Fan coil valve
Floor heating valve
Mode
Temperature Control Mode (Floor heating/integrated)
Auto Mode
Weekly program, up 6 heating periods can be set per day.
Heating periods, points of time and temperature can be individually setaccoring
to personal requirements.
Manual Mode
In this mode, thermostat operates acc. to manually set temperature.
In this mode, auto mode is switched-off.
Temporary Mode
Thermostat operates for limited time acc. to manually set temperatures and return
to auto mode until next intervention.
User Operation
Us er Opera tion
Power on/off:
Press for 3 seconds "
Power on/off : Press for 3 seconds "
Temp. setting:
Rotate wheel for change of set temperature by 0.5°C.
Temp. setting : Rotate handwheel
System mode:
Press "
" shortly to switch manual/auto mode. (Floor heating)
System mode : Press
"
" shortly to switch manual/auto mode. (Floor heating)
Press "
" shortly to switch cooling/heating/ventilation.
Press
"
" shortly to switch cooling/heating/ventilation. (fan coil)
Press "
" shortly to switch cooling/heating/ventilation/floor
Press
heating / floor heating + heating. (Integrated)
"
" shortly to switch cooling/heating/ventilation/
ventilation/floor heating/floor heating + heating. (Integrated)
Enter menu:
Press "
" for 3 seconds to enter the menu interface.
Enter menu :
Press
"
" 3 seconds to enter the menu interface.
Temp control mode:
Press "
" shortly to switch manual/auto mode. (Integrated,
Temp control
:
floor heating)
Press
"
"
shortly to switch manual/auto mode. (Integrated, floor heating)
mode
Child-proof lock:
Press "
" + "
Child-lock :
Press "
+
"
"
1 8:0 0
6 8%
ROOM
25.5 °C
Version:R7C 1.1(10/2022)
Application
Modèle Application
Capteur sol + Programmation hebdomadaire
716
Capteur sol + Programmation hebdomadaire
+ 485 Modbus (716S seulement)
716S
+ 485 Modbus (716S seulement)
703
A NC/NO dual-output + Programmation
A NC/NO dual-output + Programmation
703S
hebdomadaire + 485 Modbus (703S seulement)
hebdomadaire + 485 Modbus (703S seulement)
723
Pogrammation hebdomadaire+Potentialfree
Pogrammation hebdomadaire+Potential-
723S
output + 485Modbus (723S seulement)
free output + 485Modbus (723S seulement)
743
Minuterie + double système
Minuterie + double système
Minuterie + double système + Potential-free output
853
Minuterie + double système + Potential-free output
+ capteur sol (option) + room card (option) +
853S
+ capteur sol (option) + room card (option)
485Modbus(853S seulement)
+ 485Modbus(853S seulement)
Minuterie + 4 systèmes+ Potential-free output
863
Minuterie + 4 systèmes+ Potential-free output
+ capteur sol (optional) + carte mère (optional)
863S
+ capteur sol (optional) + carte mère (optional)
+485Modbus(863S seulement)
Plancher chauffant & ventilation, programmation
+485Modbus(863S seulement)
963
hebdomadaire + Potential-free output +
Plancher chauffant & ventilation, programmation
963S
minuterie + limit sensor (optional)+ Room card
hebdomadaire + Potential-free output +
(optional) + 485Modbus(963S only)
minuterie + limit sensor (optional)+ Room card
(optional) + 485Modbus(963S only)
Child-proof lock
Frost protection
Wi-Fi
Room humidity
Room temp.
Working mode
Fan
Auto Mode
Manual Mode
Temporary Mode
Fan speed
Power on/off key
" for tuning thermostat either on or off.
" for tuning thermostat either on or off
to change setting temperature by 0.5°C.
"
"
" for 3 seconds to activate child-proof lock.
for 3 seconds to activate child-proof lock
"
R7C.716 Color Screen Smart Thermostat
Quick configuration of Wi-Fi connection via BLE Technology
super convenient
Programmable device, multiple periods allowed to set per
day
2.8 inches large colorful LCD screen, delicate visual effect
The device can be controlled by voice via Amazon Alexa
and Google Assistant
Parameter
Supply voltage
Power consumption
Temp. setting range
Floor limited ranger
On/on deviation
Ambient temperature
Protection level
Shell material
71.04.00138
Wi-Fi setting
Press
"
"
for 3 seconds to acces menu. Turn the
and then choose " Bluetooth Mode ", press
distribution network state.
Wi-Fi setting
Bluetooth Mode(S uggest)
Access Point Mode
Time Task Setting (Fan coil/integrated)
Under power-on status, long press menu button
Continue by choosing auto mode followed by schedule. Set the parameters and press
menu button. Return to previous page. Finally, press wind speed button
activate the timer switch function.
S chedule Ta sk
Time S etting
Repea t
Action
Advanced settings (professional operation)
In power-on status press menu button several seconds. Enter menu page and
choose engineer mode. Enter password 123456 for access to advanced setting page.
Finalize setting and press button to save and exit.
Funktion list
Handwheel "
ModBus address
Adjustment range 0~250
-9.9 °C ... +9.9 °C
Sensor calibration
(14.2 °F ... 40,8 °F)
0,5°C ... +10°C
Temp. difference
(+32,9°F ... +50°F)
+47 °C ... +95 °C
Max. setting value
(117 °F ... 203 °F)
+5 °C ... +47 °C
Min. setting value
(41 °F ... 117 °F)
Anti-freeze
ON/OFF
protection
Temperature uni
°C / °F
Built-in sensor
Sensor mode
Floor sensor
Built-in control & floor limitation
Floor temperature
+20 °C ... +90 °C
(68 °F ... 194 °F)
limit
Monday to Friday
Weekday mode
Monday to Saturday
Monday to Sunday
00: Fan speed controllable
Fan control settings
01: Fan speed uncontrolled
Linkage time delay
0 ... 5 min, 0 min
None
Child-proof lock
Lock All
All but power
Function Off
Boot type
Function On
Function Saved
OFF
Room card status
Enter energy saving temperature
Remove card shutdown
Room card heating
+10 °C ... +21 °C
(50 °F ... 69 °F)
ECO temp
Room card cooling
+22 °C ... +32 °C
(72 °F ... 89 °F)
ECO temp
Air condition mode
all/cold only
Temp control
manual/auto
Reset all settings
yes/no
AC1 00~240V;50/60Hz
Wi-Fi 3W Max
5~95°C(41 ~203°F)
20~90°C(68~1 94°F
0.5~1 0°C(1 ~1 0°F),
Factory setting± 1 °C
-5~50°C(68~1 22°F)
IP 20
Anti-Flammable PC
"
"
choose "Wi-Fi setting",
confirm. The device enters the
"
"
Bluetooth Mode
Access Point Mode
Bluetooth Mode
Access Point Mode
Plea se don't lea ve,
Plea se don't lea ve,
Bluetooth is in the network...
Access Point is in the network...
to enter the menu page.
"
"
S chedule
00:00
00:00
ON
OFF Everyday
E veryda y
Add
OFF
Default
Integrated Fan coil
"
Value
963
863
0
963S
863S
-3 °C
±1 °C
50 °C
5 °C
OFF
°C
IN
35 °C
2- day
00
0min
None
Last
OFF
18 °C
26 °C
All
Manual
/
EN
to
"
"
Floor heating
853
743 716
703
723
853S
716S
703S
723S