Read and understand these instructions and the relevant manual before installing,
operating, or maintaining the device. The manual is available on the internet at
https://support.industry.siemens.com (Product Support).
Further Support
If special problems arise, or further information are required, please contact your Siemens
representative. The Siemens Customer Support Center provides around-the-clock support.
Disclaimer of Liability
Although we have carefully checked the contents of this publication for conformity with the
hardware and software described, we cannot guarantee complete conformity since errors
cannot be excluded.
The information provided in this manual is checked at regular intervals and any corrections
that might become necessary are included in the next releases. Any suggestions for
improvement are welcome. Subject to change without prior notice.
Copyright
Copyright © Siemens AG 2023 – All Rights Reserved.
The reproduction, transmission or use of this document or its contents is not permitted
without express written authority. Offenders will be liable for damages. All rights, including
rights created by patent grant or registration of a utility model or design, are reserved.
Open-Source Software
This product contains, among other things, open-source software developed by third
parties. The open-source software used in this product and the license agreements
concerning this software can be found in the Readme_OSS. These open-source software
files are protected by copyright.
Your compliance with those license conditions will entitle you to use the open-source
software as foreseen in the relevant license. In the event of conflicts between Siemens
license conditions and the open-source software license conditions, the open-source
Software conditions shall prevail with respect to the open-source software portions of the
software. The open-source software is licensed royalty-free.
Insofar as the applicable open-source software license conditions provide for it you can
order the source code of the open-source software from your Siemens sales contact –
against payment of the shipping and handling charges – for a period of at least 3 years
since purchase of the product.
We are liable for this product including the open-source software contained in it pursuant to
the license conditions applicable to the product. Any liability for the open-source software
beyond the program flow intended for this product is explicitly excluded. Furthermore, any
liability for defects resulting from modifications to the open-source software by you or third
parties is excluded. We do not provide any technical support for this product if it has been
modified.
Notes on Safety
This document contains notes that must be adhered to for your own personal safety and to
avoid damage to property. Keep it safe for later usage.
However, it does not constitute a complete description of all safety measures required for
installation, service, and maintenance of the device in question. Details are to be taken from
the device manual; those are mandatory.
Warning: Danger of severe personal injury or substantial damage to property
Hazardous voltages may occur in devices and modules during operation depending on
the design and application. Always observe the instructions given in "Qualified
Electrical Engineering Personnel" below.
Qualified Electrical Engineering Personnel
Qualified electrical engineering personnel may commission and operate the device
described in this document. Qualified electrical engineering personnel in the sense of this
document are people who can demonstrate up to date technical qualifications as electrical
technicians including safety and first aid training. These persons may commission, isolate,
ground and label devices, systems, and circuits according to the standards of safety
engineering.
Use as Prescribed
The device may only be used for such applications as set out in the catalogs and the
technical description, and only in combination with third party equipment recommended and
approved by Siemens.
Correct and safe operation of the product requires adequate transportation, storage,
installation and mounting in a control cabinet, as well as appropriate use and maintenance.
During operation of electrical equipment, it is unavoidable that certain parts of this
equipment will carry dangerous voltages. Severe injury or damage to property can occur if
the appropriate measures are not taken:
• Before making any connections, ground the equipment at the grounding terminal.
• Hazardous voltages can be present on all switching components connected to the power
supply.
• The device does not represent a safety-oriented application.
• Even after the supply voltage has been disconnected, hazardous voltages can still be
present in the equipment (capacitor storage).
• The limit values indicated in the manual must not be exceeded; that also applies to
testing and commissioning.
Statement of Conformity
The product described conforms to the following regulations:
• EMC Directive 2014/30/EU (used harmonized standard IEC/EN 60870-2-1)
• Low Voltage Directive 2014/35/EU (used harmonized standard IEC/EN 61010-1,
IEC/EN 61010-2-201)
• RoHS Directive 2011/65/EU (used harmonized standard IEC/EN 63000)
Hereby, Siemens declares that the radio equipment type CP-8022 is in compliance
with RED Directive 2014/53/EU (observance of the harmonized standard EN 301 511,
EN 301 908-1, EN 301 908-2, EN 301 908-13, EN 303 413).
The full text of the EU declaration of conformity is available on the internet under
https://support.industry.siemens.com (search term: CP-8022, search area: Certificate).
CP-8021 / CP-8022 Product Information
C53207-A5063-C481-7B-7483 / DC8-021-2.09; Edition 03.2023
CP-8021 Master Module / CP-8022 Master Module (LTE/GPRS)
Other Standards
The technical data of the product is approved in accordance with UL.
For more information, see UL Product iQ on the Internet:
https://productiq.ulprospector.com/en.
Log in (or use the option Search abridged site without login) and
search for UL file number E496940.
Used Symbols
Caution, risk of danger. The
documentation must be observed.
CE conformity
Application
CP-8021/CP-8022 is a master module of the SICAM A8000 Series. It processes signals and
communicates with higher-level devices. It can be expanded with up to 8 external I/O
modules by means of coupling modules.
The SICAM A8000 series is suitable for electrical distribution substations, gas distribution
substations, hydropower plants, pipelines, and railway power supplies.
Unpacking a Device
• Check the package for external transport damage. A damaged packing may indicate that
the device inside is also damaged.
• Unpack the device carefully; do not use force.
• Visually check the device to ensure that it is in perfect mechanical condition.
• Return a damaged device to the manufacturer or dispose it correctly. A defect device
may not either be used nor repaired by the user.
Note: Before commissioning the device, leave it in the final operation room for at least
2 hours. This allows it to reach room temperature and to prevent dampness and
condensation.
Mounting
The device is designed for horizontal mounting on a DIN-rail according to IEC 60715. A
DIN-rail with 15 mm depth is strongly recommended.
The DIN-rail must be screwed several times on metallic underground (cabinet/rack). The
metallic underground itself must be grounded properly. A mounting plate is recommended.
For thermal reasons, a minimum distance of 30 mm must be maintained around the device.
When using a cable duct with 100 mm depth below the device, it is necessary to keep a
50 mm minimum distance between device and cable duct to operate the locking hook.
At first you must click the included bus connector on the DIN-rail. Then the device itself is
connected to the bus connector.
Subsequently the power supply module is mounted, and then (optional) the I/O modules.
Note: For details about the mounting refer to the corresponding product manual.
SICAM A8000 Series
Ind. Cont. Eq.
E496940
Protection class III / extra low voltage
(ELV)
3