WF UNIQ36 / WF UNIQ37 dimensions
UNIQ36 / UNIQ37 UNIQ36 / UNIQ37 Pedestal
Height
980 mm
Width
505 mm
Depth
445 mm
Closed combus-
tion option
STOVE PERFORMANCE AND TESTING
Westfire WF UNIQ36 / WF UNIQ37 have been approved in accordance with EN 13240.
Stove model
UNIQ36 / UNIQ37
UNIQ36 Pedestal / UNIQ37 Pedestal
UNIQ36 / UNIQ37 Wall Mounted
UNIQ37 Large
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING:
This stove must not be installed into a chimney that serves any other heating appliance. An extractor fan may not be
fitted in the same room as the stove, as this can cause the stove to emit fumes into the room.
CHIMNEY
Chimney Connection - Flue Diameter: 125 mm
IMPORTANT: Once the stove is unpacked and checked it is necessary to remove the central bar from the flue collar
of the stove before installation. To remove: unbolt collar, remove bar and replace collar.
The stove comes pre-fitted with a European flue collar. Supplied with the stove, in a box, is a UK 125 mm / 5" flue
collar. Please ensure that you replace the collar when removing the central bar. Use a recognised brand of heat
resistant fire cement and ensure that enough cement is used to completely fill the area.
In order for the stove to perform satisfactorily, the chimney height must be sufficient to ensure an adequate
draught so as to clear the products of combustion and prevent smoke problems into the room.
Minimum draft: WF UNIQ36 / WF UNIQ37 Pedestal stoves have been tested with a draft of 12 Pa.
Maximum draft 25 Pa.
Flue gas flow 7.0 g/sec.
Flue gas temperature: 303°C. Approximately 12 Pa.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of
the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as
the basis for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building
Regulations Approved Document J.
If the installation is made inside an existing chimney it must be sound and have no cracks or other faults which
might allow fumes into the house. Especially older properties may have chimney faults or have cross sections that
may be too large i.e. more than 160 mm x 160 mm. Remedial action should be taken if required and expert advice
must be seeken if necessary. If it is found necessary to line the chimney, then a flue liner suitable for solid fuel must
be used in accordance with Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and must be swept clean immediately before installation of the
stove. If the stove is fitted inside an open fireplace, then the chimney should be swept one month after installation to
WESTFIRE · WF36 WF37
Pedestal 1: 1150 mm
505 mm
445 mm
Order specific closed combustion option
Weight
90 kg
95 kg
85 kg
100 kg
11 | 32
UNIQ36 / UNIQ37 Wall Mount.
765 mm
505 mm
445 mm
Nominal heat output
Wood
Smokeless fuels
7.2 KW
7.2 KW
7.2 KW
7.2 KW
UK
UNIQ37 Large
1310 mm
505 mm
445 mm
Not available
N/A
N/A
N/A
N/A