WESTFIRE · WF36 WF37
WF36 WF37
DK: INSTALLATIONS- OG BRUGSVEJLEDNING ...................................3
FR: NOTICE D'INSTALLATION ET D'UTILISATION ..............................20
DANSK INGENIØRKUNST
1

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Westfire WF36

  • Seite 1: Inhaltsverzeichnis

    WESTFIRE · WF36 WF37 WF36 WF37 DK: INSTALLATIONS- OG BRUGSVEJLEDNING ........3 UK: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS ..6 INSTALLATIONS- UND GEBRAUCHSANWEISUNG .....17 FR: NOTICE D’INSTALLATION ET D’UTILISATION ......20 NL: INSTALLATIEHANDLEIDING EN GEBRUIKSAANWIJZING ...23 DANSK INGENIØRKUNST...
  • Seite 2 WESTFIRE · WF36 WF37 WF36 WF37 DK: INSTALLATIONS- OG BRUGSVEJLEDNING ........3 UK: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS ..6 INSTALLATIONS- UND GEBRAUCHSANWEISUNG .....17 FR: NOTICE D’INSTALLATION ET D’UTILISATION ......20 NL: INSTALLATIEHANDLEIDING EN GEBRUIKSAANWIJZING ...23 WESTFIRE 2017 | WF36 WF37...
  • Seite 3: Dk: Installations- Og Brugsvejledning

    WESTFIRE WF37 · WESTFIRE WF37 med sokkel Vi ønsker Dem tillykke med Deres nye brændeovn fra Westfire ApS. For at De kan få størst mulig glæde af Deres nye brændeovn og for at der ikke skal opstå problemer, beder vi Dem gennemlæse denne vejledning.
  • Seite 4 WF36/ WF36 med sokkel og WF37/ WF37 med sokkel ovne er beregnet til intermitterende forbrænding (der skal ilægges træ ofte og ovnen er ikke fremstillet til døgnkontinuerlig opvarming). WF36/ WF36 med sokkel og WF37/ WF37 med sokkel er forsynet med en reguleringsventil til sekundærluft der skal sikre ilt til forbrændingen.
  • Seite 5: Vedligeholdelse

    WESTFIRE · WF36 WF37 GRUNDINDSTILLING AF SPJÆLDENE UNDER DRIFT: Det er nødvendigt at gøre sine egne erfaringer med hensyn til indstilling af sekundærluft, da f.eks skorstenskvalitet, skorstenshøjde, brændselskvalitet og de ydreforhold spiller en stor rolle, men man kan se om forbrændingen sker på...
  • Seite 6: Uk: Installation Manual And Operating Instructions

    This manual refers to the stove type listed above, which has been tested in accordance with EN 13240. Congratulations on your purchase of a new wood burning stove from Westfire ApS. Please read this manual carefully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems. Please note that “all local regulations, including those referring to national and European Standards, need to be complied with...
  • Seite 7 In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate draught so as to clear the products of combustion and prevent smoke problems into the room. Minimum draft: UNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal stoves has been tested with a draft of 12 Pa. Maximum draft 25 Pa.
  • Seite 8 The Westfire UNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal wood stoves has been tested and is suitable to be installed on a 12 mm non combustible plate such as Westfire 12 mm glass plates or 20 mm slate plates. Installa- tion of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J.
  • Seite 9 Right = Open / Left = Closed Westfire Insulated chambers The Westfire UNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal wood burning stoves is lined with heat deflection panels and baffles, these panels are designed to ensure the maximum efficiency and are an integral part of the clean burn process of the stove.
  • Seite 10: Initial Lighting

    At nominal heat output, expect to refuel your stove approximately once an hour. WF36 / WF37 models are all equipped with air control levers for secondary and primary air and they are designed to ensure a plentiful supply of oxygen during firing. When lit, the stove will get very hot and due care must therefore be exercised.
  • Seite 11 Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements The Westfire Uniq 36 /37 woodstoves have been recommended as suitable for use in smoke control areas when burning wood logs. The SE appliances include a modified air control to prevent closure of the secondary air control beyond 40% open, alterations should not be attempted.
  • Seite 12 Door operation When opening the door of your Westfire stove always wear the glove that is provided to protect your hand from possible heat. The handle pulls out right away from the fire. When shutting the door push the door closed and push the handle until the handle firmly closes.
  • Seite 13: Warning Note

    WESTFIRE · WF36 WF37 TROUBLE SHOOTING, CHECK THE FOLLOWING: 1. Fire Will Not Burn the air inlet is not obstructed in any way, that chimneys and flueways are clear, that a suitable fuel is being used, that there is an adequate air supply into the room, that an extractor fan is not fitted in the same room as the fire.
  • Seite 14 The guarantee does not cover damage to replaceable parts, transport costs associated with repairs under warranty or the installation/dismantling of the stove in connection with repairs under warranty. Warning! Any unauthorised modification of the appliance is forbidden. Only replacement parts recommended by Westfire ApS should be used for repairs...
  • Seite 15 WESTFIRE · WF36 WF37 Number Code Description W93700-02-03-99-00 Rear fire brick W93700-02-24-99-00 Right side rear brick Part brick set Left side rear brick WF 37 Side bricks front x 2 W93700-02-22-99-00 Base right brick Part brick set Base left brick...
  • Seite 16 WESTFIRE · WF36 WF37 VERMICULITE FIRE BRICK INSTALLATION SEQUENCE – WESTFIRE UNIQ36/ WF36 Pedestal and UNIQ37/ WF37 Pedestal Place Top baffle in position against L shaped lugs leaving 5 cm gap at rear of stove. Place rear brick Ensure side brick...
  • Seite 17: D: Installations- Und Gebrauchsanweisung

    Diese Anweisung bezieht sich auf nachfolgend genannte Modelle, die gemäß den Vorschriften der Norm CE/EN 13240 geprüft wurden. Wir beglückwünschen Sie zum Erwerb Ihres neuen Westfire Kaminofens. Damit Sie viel Freude daran haben, bitten wir Sie, diese Gebrauchsanweisung sorgfältig durchzulesen, denn so lassen sich Probleme vermeiden.
  • Seite 18: Grundeinstellung Der Regulierklappen Bei Betrieb

    Regulierstange der Sekundärluftzufuhr zu etwa 38% eingeschoben. Nach jeweils 1 Stunde ist bei Nennwärme- leistung Brennholz nachzulegen. Die Modelle WF36 / WF36 sockel und die Modelle WF37 / WF37 sockel , die häufiges Nachlegen erfordern, sind nicht für Dauerbetrieb (rund um die Uhr) ausgelegt.
  • Seite 19: Wartung Und Pflege

    Bedienung, nicht sachgemäßen Anschluss oder äußere Einwirkungen ergeben. Ausgenommen sind ferner Verschleißteile sowie Kosten für Transport oder Auf-/Abbauarbeiten im Zuge von Garantie-Reparaturen. Die Garantie erlischt bei unbefugten technischen Änderungen am Ofen. Bei Reparaturen sind ausschließlich von der Fa. Westfire ApS empfohlene Ersatzteile zu verwenden.
  • Seite 20: Fr: Notice D'installation Et D'utilisation

    WF36 / WF37 sont homologués, et la brochure sur l’utilisation correcte du bois de chauffe, toutes deux disponibles chez votre revendeur de poêle ou chez votre ramoneur.
  • Seite 21: Conseils D'utilisation

    être chauffé en continu). Le poêle WF36 / WF36 socle et WF37 / WF37 socle est équipé d’un clapet de régulation pour l’air secondaire qui doit assurer l’apport en air comburant.
  • Seite 22: En Cas De Dysfonctionnement

    La garantie ne couvre pas les dommages sur des pièces qui peuvent être changées, ni les frais de transport suite à des réparations sous garantie, ni le montage/démontage des réparations sous garantie. Avertissement : il est interdit de procéder à des modifications non autorisées de ce système. En cas de réparation, utilisez uniquement des pièces détachées recommandées par Westfire ApS.
  • Seite 23: Nl: Installatiehandleiding En Gebruiksaanwijzing

    Dat kan zijn in de vorm van een ventiel (het ventiel moet open staan en over voldoende capaciteit beschikken als de haard brandt) of een verseluchtsysteem dat met de kachel is verbonden. Alle houtkachels van Westfire zijn voorzien van een rookkeerplaat, die ervoor zorgt dat de weg die de rook aflegt lang genoeg is.
  • Seite 24 38%. Bij een nominaal warmtevermogen moet u telkens ongeveer 1 keer per uur brandstof bijvullen. WF36 / WF36 met sokkel en WF37 / WF37 met sokkel kachels zijn berekend op verbranding met tussenpozen (er moet vaak hout worden toegevoegd en de haard is niet gemaakt voor continue verwarming gedurende 24 uur per dag).
  • Seite 25: Brandstof

    De garantie dekt geen schade aan vervangbare onderdelen, transportkosten in verband met garantiereparaties of montage/demontage bij garantiereparaties. De garantie vervalt bij onbevoegde veranderingen aan de warmtebron. Gebruik bij reparatie uitsluitend reserveonderdelen die door Westfire ApS worden aanbevolen.
  • Seite 26 Århus, den 7. oktober 2015 Montør påtegning Kim Sig Andersen Konsulent Y:\Organization\C068\Biomasse og Bioraffinering\ELAB\Drift\Attester\Brovn\Attester Norge\Westfire 2187 WF37 ver. 1.docx 07-10-2015 15:57:18 Dette PDF dokument er kun gyldigt, hvis det er digitalt signeret med OCES digitalsignaturen for Kim Sig Andersen, Teknologisk Institut.
  • Seite 27 1 MW, for så vidt: Krav fra 2015 til januar 2017 opfyldt: Krav efter januar 2017 opfyldt: Westfire 2187 WF37.docx 14-08-2015 13:50:29 Dette PDF dokument er kun gyldigt, hvis det er digitalt signeret med OCES digitalsignaturen for Kim Sig Andersen, Teknologisk Institut.
  • Seite 28 This PDF document is only valid if digitally signed with the OCES digital signature for Kim Sig Andersen, Danish Technological Institute. TØMRERVEJ 3 | DK-6800 VARDE | TELEFON +45 7522 5352 | FAX +45 7522 1352 | WWW.WESTFIRE.DK | E-MAIL: INFO@WESTFIRE.DK...