Maintenance and repair

6
Maintenance and repair
DANGER
Danger of death by electric shock
There is imminent danger in case of con-
tact with live parts – even in the event of a
fault.
The pump must not be used if there
are persons in the water.
When working on the pump, comply
with legal regulations.
Work on electrical components must
be performed by qualified electricians
only.
Disconnect the pump and, if neces-
sary, the system from the power
source before working on the electrical
components.
 
WARNING
Risk of crushing or drawing in at the
rotor
 
Danger
of
cutting
reaching into the impeller
Disconnect the pump from the power
source before carrying out any mainte-
nance work.
Secure the pump against accidental
switch-on.
 
WARNING
Risk of overturning of the pump
Place the pump on a stable surface.
 
Secure the pump against falling over or
rolling away.
 
WARNING
Risk of injury due to breaking of the
carrying handles
 
Before lifting the pump, check the car-
rying handle for wear and damage.
Operating Instructions for Submersible Pump Series P
 
 
 
injuries
when
Regular inspections and preventive maintenance
ensure reliable and safe operation. Inspect the
pump at least every six months.
Maintenance and repair work must only be carried
out by trained specialist personnel in accordance
with the maintenance schedule.
Any work on the electrical equipment of the pump
must only be carried out by qualified electricians.
For major maintenance and inspections, you can
contact an authorised P dealer or workshop.
Carry out maintenance and repair work only with the
pump switched off. Observe the accident prevention
regulations.
CAUTION
Hazard due to start-up jerk after
switch-on
 
Disconnect the pump from the power
source before carrying out any mainte-
nance work.
Secure the pump against accidental
switch-on.
CAUTION
Risk of cutting injuries at sharp edges
Worn impellers often have very sharp
 
edges.
Wear protective gloves when mounting
and dismounting the impeller.
CAUTION
Hazard due to splashing oil
The oil inside the housing may still be un-
 
der pressure and splash out when the oil
filler plug is opened.
When loosening the oil filler plug, hold
a cloth over the oil housing to prevent
splashing.