Commissioning and operation

DANGER
Danger of death by electric shock
There is imminent danger in case of con-
tact with live parts – even in the event of a
fault.
The pump must not be used if there
are persons in the water.
 
WARNING
Risk of crushing or drawing in at the
rotor
 
Danger
of
cutting
reaching into the impeller
Only start up the pump if all safety de-
vices are properly installed and opera-
tional.
 
WARNING
Risk of overturning of the pump
Place the pump on a stable surface.
 
Secure the pump against falling over or
rolling away.
 
CAUTION
Hazard due to start-up jerk after
switch-on
 
The impact when switching on can be ex-
tremely strong.
Never hold the handle when switching
on the pump.
Place the pump on a stable surface to
prevent it from sliding or shifting.
 
CAUTION
Hazard due to splashing liquids under
high pressure
 
In case of leaks or damaged compo-
nents, switch off the pump and secure
it against continued operation.
40 / 359
5.1
1.
2.
The pump can be suspended by the handle and po-
sitioned slightly above the ground. Depending on
the pump capacity, a possibly high start-up jerk of
the pump must be observed here!
5.2
The correct direction of rotation of the pump is given
when the start-up jerk is in counter-clockwise direc-
tion (as seen from above).
injuries
when
If the direction of rotation is wrong, two of the
phases must be reversed (400 V) (have this work
done by a qualified electrician).
Operating Instructions for Submersible Pump Series P
Commissioning and operation

Installation of the pump

Connect the pressure line.
Connect the power cable.

Check direction of rotation