7. | High-Voltage Measurement

7.2. Performing High-Voltage Measurements

DANGER
Danger to life due to electric voltage on vehicles with high-voltage systems
It is a precondition for performing high-voltage measurements that the user has knowledge of automotive
technology and is therefore aware of the sources of danger and risks in the workshop and on motor vehi-
cles. An additional country-specific qualification is mandatory.
Ensure, that the component to be evaluated is de-energized.
Ensure that you or other persons do not touch any sockets or connecting cables of the high-voltage battery
module.
Ensure that you or other persons do not touch energized components.
Do not remove the protective cap from the test prods during high-voltage measurements.